Higher sensitivity in the detection of inflammatory brain lesions in patients with clinically isolated syndromes suggestive of multiple sclerosis using high field MRI:: an intraindividual comparison of 1.5 T with 3.0 T

被引:80
作者
Wattjes, Mike P.
Lutterbey, Goetz G.
Harzheim, Michael
Gieseke, Juergen
Traeber, Frank
Klotz, Luisa
Klockgether, Thomas
Schild, Hans H.
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
[2] Univ Bonn, Dept Neurol, D-5300 Bonn, Germany
[3] Philips Med Syst, Best, Netherlands
关键词
high-field MRI; multiple sclerosis; clinically isolated syndrome; magnetic field strength;
D O I
10.1007/s00330-006-0195-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to determine the sensitivities in the detection of inflammatory lesions in patients with clinically isolated syndromes suggestive of multiple sclerosis at 3.0 T and 1.5 T. MR imaging of 40 patients at both field strengths was performed in separate sessions including contiguous axial slices of T2 turbo spin-echo (T2 TSE), fluid-attenuated-inversion-recovery (FLAIR) and pre- and postcontrast T1 spin-echo (T1 SE). Inflammatory lesions > 3 mm in size were counted and categorized according to their anatomic location. Lesion conspicuity was assessed on a five-point scale. At 3.0 T, 13% more white matter lesions could be identified on the FLAIR sequence and on the T2 TSE sequence. Compared to 1.5 T 7.5% more contrast-enhancing lesions were detected at 3.0 T. The higher detection rate at 3.0 T was significant for the infratentorial (p=0.02) and juxtacortical (p < 0.01) region on the FLAIR as well as for the infratentorial (p=0.03), juxtacortical (p=0.02) and periventricular (p=0.03) region on the T2 TSE sequence. The lesion conspicuity was significantly better at 3.0 T for FLAIR and T2 TSE sequences (p < 0.01; p=0.01). In conclusion, high-field MRI at 3.0 T provides a significantly higher detection rate of inflammatory brain lesions especially in the infratentorial, juxtacortical and periventricular anatomic region.
引用
收藏
页码:2067 / 2073
页数:7
相关论文
共 33 条
[1]   Comparison of MRI criteria at first presentation to predict conversion to clinically definite multiple sclerosis [J].
Barkhof, F ;
Filippi, M ;
Miller, DH ;
Scheltens, P ;
Campi, A ;
Polman, CH ;
Comi, G ;
Ader, HJ ;
Losseff, N ;
Valk, J .
BRAIN, 1997, 120 :2059-2069
[2]   Interobserver agreement for diagnostic MRI criteria in suspected multiple sclerosis [J].
Barkhof, F ;
Filippi, M ;
van Waesberghe, JHTM ;
Campi, A ;
Miller, DH ;
Adèr, HJ .
NEURORADIOLOGY, 1999, 41 (05) :347-350
[3]   Application of the new McDonald criteria to patients with clinically isolated syndromes suggestive of multiple sclerosis [J].
Dalton, CM ;
Brex, PA ;
Miszkiel, KA ;
Hickman, SJ ;
MacManus, DG ;
Plant, GT ;
Thompson, AJ ;
Miller, DH .
ANNALS OF NEUROLOGY, 2002, 52 (01) :47-53
[4]   Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging [J].
de Zwart, JA ;
Ledden, PJ ;
Kellman, P ;
van Gelderen, P ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1218-1227
[5]   RESOLUTION-DEPENDENT ESTIMATES OF LESION VOLUMES IN MAGNETIC-RESONANCE-IMAGING STUDIES OF THE BRAIN IN MULTIPLE-SCLEROSIS [J].
FILIPPI, M ;
HORSFIELD, MA ;
CAMPI, A ;
MAMMI, S ;
PEREIRA, C ;
COMI, G .
ANNALS OF NEUROLOGY, 1995, 38 (05) :749-754
[6]   Quantitative assessment of MRI lesion load in multiple sclerosis - A comparison of conventional spin-echo with fast fluid-attenuated inversion recovery [J].
Filippi, M ;
Yousry, T ;
Baratti, C ;
Horsfield, MA ;
Mammi, S ;
Becker, C ;
Voltz, R ;
Spuler, S ;
Campi, A ;
Reiser, MF ;
Comi, G .
BRAIN, 1996, 119 :1349-1355
[7]   Interscanner variation in brain MRI lesion load measurements in MS: Implications for clinical trials [J].
Filippi, M ;
vanWaesberghe, JH ;
Horsfield, MA ;
Bressi, S ;
Gasperini, C ;
Yousry, TA ;
GawneCain, ML ;
Morrissey, SP ;
Rocca, MA ;
Barkhof, F ;
Nijeholt, GJLA ;
Bastianello, S ;
Miller, DH .
NEUROLOGY, 1997, 49 (02) :371-377
[8]   The utility of MRI in suspected MS - Report of the therapeutics and technology assessment subcommittee of the American Academy of Neurology [J].
Frohman, EM ;
Goodin, DS ;
Calabresi, PA ;
Corboy, JR ;
Coyle, PK ;
Filippi, M ;
Frank, JA ;
Galetta, SL ;
Grossman, RI ;
Hawker, K ;
Kachuck, NJ ;
Levin, MC ;
Phillips, JT ;
Racke, MK ;
Rivera, VM ;
Stuart, WH .
NEUROLOGY, 2003, 61 (05) :602-611
[9]   Comparison of volume, four- and eight-channel head coils using standard and parallel imaging [J].
Gizewski, ER ;
Maderwald, S ;
Wanke, I ;
Goehde, S ;
Forsting, M ;
Ladd, ME .
EUROPEAN RADIOLOGY, 2005, 15 (08) :1555-1562
[10]   Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging:: comparison of 1.5 T vs. 3.0 T [J].
Gutberlet, M ;
Schwinge, K ;
Freyhardt, P ;
Spors, B ;
Grothoff, M ;
Denecke, T ;
Lüdemann, L ;
Noeske, R ;
Niendorf, T ;
Felix, R .
EUROPEAN RADIOLOGY, 2005, 15 (08) :1586-1597