Polysilicon interdigitated electrodes as impedimetric sensors

被引:37
作者
de la Rica, Roberto [1 ]
Fernandez-Sanchez, Cesar [1 ]
Baldi, Antonio [1 ]
机构
[1] CSIC, IMB CNM, Barcelona 08193, Spain
关键词
interdigitated electrodes; polysilicon; impedimetric sensor; conductometric sensor; biosensor;
D O I
10.1016/j.elecom.2006.05.028
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 [应用化学];
摘要
The suitability of polysilicon as a material for the fabrication of interdigitated electrodes and their application to the development of sensors is studied in this work. The main interest in using this material lies in the possibility of obtaining integrated sensors with commercial CMOS technologies and simple post-processing steps. Electrodes with 3 mu m finger width and 3, 10, and 20 mu m spacing were fabricated and characterised. Conductivity measurements in the range from 4 to 50 mu S/cm yielded a linear response with cell constants of 0.0416 cm(-1), 0.155 cm(-1) and 0.33 cm(-1), respectively. Permittivity measurements in the range from epsilon(r) = 80.1 to epsilon(r) = 1.89 yielded a linear response and similar cell constants. The possibility to functionalise both the electrode fingers and the space in between them using a single silanisation process is an interesting advantage of polysilicon electrodes. An urease-based biosensor was obtained with this procedure and characterisation results are reported. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1239 / 1244
页数:6
相关论文
共 19 条
[1]
A bi-enzymatic whole cell conductometric biosensor for heavy metal ions and pesticides detection in water samples [J].
Chouteau, C ;
Dzyadevych, S ;
Durrieu, C ;
Chovelon, JM .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (02) :273-281
[2]
Glucose conductometric biosensor with potassium hexacyanoferrate(III) as an oxidizing agent [J].
Dzyadevich, SV ;
Arkhipova, V ;
Soldatkin, AP ;
El'skaya, AV ;
Shul'ga, AA .
ANALYTICA CHIMICA ACTA, 1998, 374 (01) :11-18
[3]
Disposable noncompetitive immunosensor for free and total prostate-specific antigen based on capacitance measurement [J].
Fernández-Sánchez, C ;
McNeil, CJ ;
Rawson, K ;
Nilsson, O .
ANALYTICAL CHEMISTRY, 2004, 76 (19) :5649-5656
[4]
Comparison of a conventional with an advanced micromachined flexible-fuel sensor [J].
Hofmann, T ;
Beckmann, F ;
Michaelis, S ;
Zacheja, J ;
Binder, J ;
Tagliante, S .
SENSORS AND ACTUATORS A-PHYSICAL, 1997, 61 (1-3) :319-322
[5]
PERFORMANCE OF A PLANAR DIFFERENTIAL-CONDUCTIVITY SENSOR FOR UREA [J].
JACOBS, P ;
SULS, J ;
SANSEN, W .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 20 (2-3) :193-198
[6]
Janildo L. M., 2002, SURF INTERFACE ANAL, V33, P293
[7]
A CMOS-COMPATIBLE MONOLITHIC CONDUCTIVITY SENSOR WITH INTEGRATED ELECTRODES [J].
KORDAS, N ;
MANOLI, Y ;
MOKWA, W ;
ROSPERT, M .
SENSORS AND ACTUATORS A-PHYSICAL, 1994, 43 (1-3) :31-37
[8]
Lee WY, 2000, ELECTROANAL, V12, P78, DOI 10.1002/(SICI)1521-4109(20000101)12:1<78::AID-ELAN78>3.0.CO
[9]
2-B
[10]
Sensitive DNA electrical detection based on interdigitated Al/Al2O3 microelectrodes [J].
Moreno-Hagelsieb, L ;
Lobert, PE ;
Pampin, R ;
Bourgeois, D ;
Remacle, J ;
Flandre, D .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 98 (2-3) :269-274