Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty

被引:15
作者
Graydon, A. J. [1 ]
Malak, S. [2 ]
Anderson, I. A. [2 ]
Pitto, R. P. [1 ]
机构
[1] Univ Auckland, Dept Orthopaed Surg, Middlemore Hosp, S Auckland Clin Sch, Auckland 1, New Zealand
[2] Univ Auckland, Bioengn Inst, Auckland 1, New Zealand
关键词
REPLACEMENT; ALIGNMENT; VARIABILITY; SUPPORT;
D O I
10.1007/s00264-008-0586-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The objective of this study was to develop a method to assess the accuracy of an electromagnetic technology image-free navigation system for total knee arthroplasty in a leg with normal or abnormal mechanical alignment. An acrylic phantom leg was constructed to simulate tibia and femur deformation. Determination of actual leg alignment was achieved using a digital caliper unit. In the setting of normal alignment, the mean error of the system characterised as the difference between the measured computer navigation and digital caliper angles ranged between 0.8A degrees (frontal plane) and 1.5A degrees (lateral plane). In the setting of abnormal alignment, the mean error ranged between 0.4A degrees (frontal plane) and 1.6A degrees (lateral plane). Deformity had no demonstrable effect on accuracy. The study demonstrates satisfactory in vitro system accuracy in both normal and abnormal leg mechanical alignment settings.
引用
收藏
页码:975 / 979
页数:5
相关论文
共 21 条
[1]
Alan Rodney K, 2007, J Knee Surg, V20, P152
[2]
Navigated total knee replacement - A meta-analysis [J].
Bauwens, Kai ;
Matthes, Gerrit ;
Wich, Michael ;
Gebhard, Florian ;
Hanson, Beate ;
Ekkernkamp, Axel ;
Stengel, Dirk .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (02) :261-269
[3]
Experimental assessment of precision and accuracy of radio stereometric analysis for the determination of polyethylene wear in a total hip replacement model [J].
Bragdon, CR ;
Malchau, H ;
Yuan, XH ;
Perinchief, R ;
Kärrholm, J ;
Börlin, N ;
Estok, DM ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (04) :688-695
[4]
Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique [J].
Chin, PL ;
Yang, KY ;
Yeo, SJ ;
Lo, NN .
JOURNAL OF ARTHROPLASTY, 2005, 20 (05) :618-626
[5]
HAKKER RG, 2005, CLIN ORTHOP RELAT R, V433, P152
[6]
Total knee arthroplasty implanted with and without kinematic navigation [J].
Hart, R ;
Janecek, M ;
Chaker, A ;
Bucek, P .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (06) :366-369
[7]
Alignment and orientation of the components in total knee replacement with and without navigation support - A prospective, randomised study [J].
Kim, Y.-H. ;
Kim, J.-S. ;
Yoon, S.-H. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (04) :471-476
[8]
LIONBERGER R, 2006, NAVIGATION MIS ORTHO, P44
[9]
A prospective, randomized study of computer-assisted and conventional total knee arthroplasty - Three-dimensional evaluation of implant alignment and rotation [J].
Matziolis, Georg ;
Krocker, Doerte ;
Weiss, Ulrike ;
Tohtz, Stephan ;
Perka, Carsten .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (02) :236-243
[10]
Accuracy of a computer-assisted navigation system for total knee replacement [J].
Pitto, RP ;
Graydon, AJ ;
Bradley, L ;
Malak, SF ;
Walker, CG ;
Anderson, IA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (05) :601-605