Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique

被引:191
作者
Chin, PL [1 ]
Yang, KY [1 ]
Yeo, SJ [1 ]
Lo, NN [1 ]
机构
[1] Singapore Gen Hosp, Dept Orthopaed Surg, Singapore 169608, Singapore
关键词
knee; computer navigation; TKA;
D O I
10.1016/j.arth.2005.04.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of this study is to assess the radiological outcome of conventional techniques versus computer-navigated surgery for total knee arthroplasty. Ninety patients with knee arthritis were prospectively randomized into 3 groups: conventional technique: extramedullary (EM) and intramedullary (IM) tibia guide versus computer navigation surgery (CAS). Two surgeons performed all procedures. Standardized long leg coronal and sagittal x-rays were evaluated by a blinded assessor. Our results showed that CAS had greater consistency and accuracy in implant placement. In the coronal view, 93.3% in the CAS group had better outcomes compared with EM (73.4%) and IM (60.0%). In the sagittal axis, 90.0% CAS also had better outcomes compared with EM (63.3%) and IM (76.7%). Computer-navigated total knee arthroplasty helps increase accuracy and reduce "outliers" for implant placement.
引用
收藏
页码:618 / 626
页数:9
相关论文
共 22 条
[1]   Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Perlick, C ;
Grifka, J .
INTERNATIONAL ORTHOPAEDICS, 2004, 28 (02) :87-90
[2]   Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[3]  
Dennis D A, 1993, J Arthroplasty, V8, P43, DOI 10.1016/S0883-5403(06)80106-3
[4]  
DORR LD, 2002, CLIN ORTHOP, V142
[5]  
DUPARC J, 1967, ANN RADIOL-RADIOL CL, V10, pR635
[6]   The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation [J].
Jazrawi, LM ;
Birdzell, L ;
Kummer, FJ ;
Di Cesare, PE .
JOURNAL OF ARTHROPLASTY, 2000, 15 (06) :761-766
[7]  
Jenny J Y, 2001, Comput Aided Surg, V6, P217, DOI 10.1002/igs.10006.abs
[8]   Influence of intramedullary versus extramedullary alignment guides on final total knee arthroplasty component position - A radiographic analysis [J].
Maestro, A ;
Harwin, SF ;
Sandovaal, MG ;
Vaquero, DH ;
Murcia, A .
JOURNAL OF ARTHROPLASTY, 1998, 13 (05) :552-558
[9]   The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties [J].
Mahaluxmivala, J ;
Bankes, MJK ;
Nicolai, P ;
Aldam, CH ;
Allen, PW .
JOURNAL OF ARTHROPLASTY, 2001, 16 (05) :635-640
[10]   Tibial shaft axis does not always serve as a correct coronal landmark in total knee arthroplasty for varus knees [J].
Matsuda, S ;
Mizu-uchi, H ;
Miura, H ;
Nagamine, R ;
Urabe, K ;
Iwamoto, Y .
JOURNAL OF ARTHROPLASTY, 2003, 18 (01) :56-62