Average patient walking activity approaches 2 million cycles per year - Pedometers under-record walking activity

被引:155
作者
Silva, M [1 ]
Shepherd, EF [1 ]
Jackson, WO [1 ]
Dorey, FJ [1 ]
Schmalzried, TP [1 ]
机构
[1] Orthoped Hosp, Ctr Joint Replacement, Los Angeles, CA 90007 USA
关键词
walking activity; joint arthroplasty; pedometer; step activity monitor;
D O I
10.1054/arth.2002.32699
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A two-dimensional accelerometer worn on the ankle (step activity monitor [SAM]; Prosthetic Research Study, Seattle, WA) has been proved to be highly accurate for assessing walking activity. The walking activity of 33 patients with well.-functioning total hip arthroplasties was measured continuously during daily life, simultaneously with a pedometer and a SAM. The SAM recorded an average of 1.9 million cycles/y. The pedometer under-recorded an average of 34% cycles per day compared with the SAM (P=.0007), but the 2 measures were highly correlated (r=0.66; P=.001). No difference was seen in the number of gait cycles per day between men and women. The previously reported difference in average walking activity between men and women is due to greater under-recording of the pedometer in women, especially those with a body mass index greater than or equal to27. The pedometer is more reliable in quantifying the walking activity of men, less obese women, and patients with >1 million gait cycles/y.
引用
收藏
页码:693 / 697
页数:5
相关论文
共 25 条
[1]   Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene [J].
Anissian, HL ;
Stark, A ;
Gustafson, A ;
Good, V ;
Clarke, IC .
ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (06) :578-582
[2]  
BANKSTON AB, 1995, CLIN ORTHOP RELAT R, P37
[3]  
BANKSTON AB, 1995, CLIN ORTHOP RELAT R, V317, P7
[4]   VALIDATION OF A SIMPLE MECHANICAL ACCELEROMETER (PEDOMETER) FOR THE ESTIMATION OF WALKING ACTIVITY [J].
BASSEY, EJ ;
DALLOSSO, HM ;
FENTEM, PH ;
IRVING, JM ;
PATRICK, JM .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1987, 56 (03) :323-330
[5]  
CALLAGHAN JJ, 1995, CLIN ORTHOP RELAT R, V317, P14
[6]  
Chan FW, 1999, CLIN ORTHOP RELAT R, P10
[7]  
Hop JD, 1997, CLIN ORTHOP RELAT R, P20
[8]   INVIVO WEAR OF POLYETHYLENE ACETABULAR COMPONENTS [J].
KABO, JM ;
GEBHARD, JS ;
LOREN, G ;
AMSTUTZ, HC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :254-258
[9]   EFFECT OF FEMORAL-HEAD SIZE ON WEAR OF THE POLYETHYLENE ACETABULAR COMPONENT [J].
LIVERMORE, J ;
ILSTRUP, D ;
MORREY, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (04) :518-528
[10]   Relationship between body mass index and activity in hip or knee arthroplasty patients [J].
McClung, CD ;
Zahiri, CA ;
Higa, JK ;
Amstutz, HC ;
Schmalzried, TP .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (01) :35-39