Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: comparison with intravascular ultrasound-derived reconstructions

被引:36
作者
Bourantas, Christos V. [1 ]
Papafaklis, Michail I. [2 ]
Lakkas, Lampros [3 ]
Sakellarios, Antonis [4 ]
Onuma, Yoshinobu [1 ]
Zhang, Yao-Jun [1 ]
Muramatsu, Takashi [1 ]
Diletti, Roberto [1 ]
Bizopoulos, Paschalis [4 ]
Kalatzis, Fanis [4 ]
Naka, Katerina K. [3 ]
Fotiadis, Dimitrios I. [4 ]
Wang, Jin [5 ]
Garcia, Hector M. Garcia [1 ]
Kimura, Takeshi [6 ]
Michalis, Lampros K. [3 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Intervent Cardiol, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[2] Harvard Univ, Brigham & Womens Hosp, Div Cardiovasc, Sch Med, Boston, MA 02115 USA
[3] Univ Ioannina, Sch Med, Dept Cardiol, GR-45110 Ioannina, Greece
[4] Univ Ioannina, Dept Mat Sci & Engn, GR-45110 Ioannina, Greece
[5] Abbott Vasc, Diegem, Belgium
[6] Kyoto Univ, Dept Cardiovasc Med, Grad Sch Med, Kyoto, Japan
关键词
Endothelial shear stress; Neointimal formation; Optical coherence tomography; Bioresorbable scaffold; ELUTING STENT IMPLANTATION; VASCULAR SCAFFOLD; CORONARY-ARTERIES; IMAGING OUTCOMES; STRUT DESIGN; BLOOD-FLOW; 2ND-GENERATION; HUMANS;
D O I
10.1007/s10554-014-0374-3
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Intravascular ultrasound (IVUS)-based reconstructions have been traditionally used to examine the effect of endothelial shear stress (ESS) on neointimal formation. The aim of this analysis is to compare the association between ESS and neointimal thickness (NT) in models obtained by the fusion of optical coherence tomography (OCT) and coronary angiography and in the reconstructions derived by the integration of IVUS and coronary angiography. We analyzed data from six patients implanted with an Absorb bioresorbable vascular scaffold that had biplane angiography, IVUS and OCT investigation at baseline and 6 or 12 months follow-up. The IVUS and OCT follow-up data were fused separately with the angiographic data to reconstruct the luminal morphology at baseline and follow-up. Blood flow simulation was performed on the baseline reconstructions and the ESS was related to NT. In the OCT-based reconstructions the ESS were lower compared to the IVUS-based models (1.29 +/- A 0.66 vs. 1.87 +/- A 0.66 Pa, P = 0.030). An inverse correlation was noted between the logarithmic transformed ESS and the measured NT in all the OCT-based models which was higher than the correlation reported in five of the six IVUS-derived models (-0.52 +/- A 0.19 Pa vs. -0.10 +/- A 0.04, P = 0.028). Fusion of OCT and coronary angiography appears superior to IVUS-based reconstructions; therefore it should be the method of choice for the study of the effect of the ESS on neointimal proliferation.
引用
收藏
页码:485 / 494
页数:10
相关论文
共 22 条
[1]
Athanasiou LS, 2012, IEEE ENG MED BIO, P2647, DOI 10.1109/EMBC.2012.6346508
[2]
Effects of different stent designs on local hemodynamics in stented arteries [J].
Balossino, Rossella ;
Gervaso, Francesca ;
Migliavacca, Francesco ;
Dubini, Gabriele .
JOURNAL OF BIOMECHANICS, 2008, 41 (05) :1053-1061
[3]
A new methodology for accurate 3-dimensional coronary artery reconstruction using routine intravascular ultrasound and angiographic data: implications for widespread assessment of endothelial shear stress in humans [J].
Bourantas, Christos V. ;
Papafaklis, Michail I. ;
Athanasiou, Lambros ;
Kalatzis, Fanis G. ;
Naka, Katerina K. ;
Siogkas, Panagiotis K. ;
Takahashi, Saeko ;
Saito, Shigeru ;
Fotiadis, Dimitrios I. ;
Feldman, Charles L. ;
Stone, Peter H. ;
Michalis, Lampros K. .
EUROINTERVENTION, 2013, 9 (05) :582-593
[4]
Comparison of Near-Wall Hemodynamic Parameters in Stented Artery Models [J].
Duraiswamy, Nandini ;
Schoephoerster, Richard T. ;
Moore, James E., Jr. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (06)
[5]
Usefulness of shear stress pattern in predicting neointima distribution in sirolimus-eluting stents in coronary arteries [J].
Gijsen, FJH ;
Oortman, RM ;
Wentzel, JJ ;
Schuurbiers, JCH ;
Tanabe, K ;
Degertekin, M ;
Ligthart, JM ;
Thury, A ;
de Feyter, PJ ;
Serruys, PW ;
Slager, CJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (11) :1325-1328
[6]
Serial Analysis of the Malapposed and Uncovered Struts of the New Generation of Everolimus-Eluting Bioresorbable Scaffold With Optical Coherence Tomography [J].
Gomez-Lara, Josep ;
Radu, Maria ;
Brugaletta, Salvatore ;
Farooq, Vasim ;
Diletti, Roberto ;
Onuma, Yoshinobu ;
Windecker, Stephan ;
Thuesen, Leif ;
McClean, Dougal ;
Koolen, Jacques ;
Whitbourn, Robert ;
Dudek, Dariusz ;
Smits, Pieter C. ;
Regar, Evelyn ;
Veldhof, Susan ;
Rapoza, Richard ;
Ormiston, John A. ;
Garcia-Garcia, Hector M. ;
Serruys, Patrick W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (09) :992-1001
[7]
Optical coherence tomography: High resolution intravascular imaging to evaluate vascular healing after coronary stenting [J].
Guagliumi, Giulio ;
Sirbu, Vasile .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (02) :237-247
[8]
Blood flow in stented arteries: A parametric comparison of strut design patterns in three dimensions [J].
He, Y ;
Duraiswamy, N ;
Frank, AO ;
Moore, JE .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (04) :637-647
[9]
Hemodynamically Driven Stent Strut Design [J].
Jimenez, Juan M. ;
Davies, Peter F. .
ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (08) :1483-1494
[10]
Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models [J].
LaDisa, JF ;
Olson, LE ;
Guler, I ;
Hettrick, DA ;
Kersten, JR ;
Warltier, DC ;
Pagel, PS .
JOURNAL OF APPLIED PHYSIOLOGY, 2005, 98 (03) :947-957