Evaluating the suitability of thick-film TiO2 capacitors for use in a wireless pressure measurement system

被引:6
作者
Arshak, K.
Morris, D.
Arshak, A.
Korostynska, O.
Jafer, E.
机构
[1] Univ Limerick, Electron & Comp Engn Dept, Limerick, Ireland
[2] Univ Limerick, Dept Phys, Limerick, Ireland
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2006年 / 26卷 / 5-7期
关键词
pressure sensor; TiO2; thick film; strain gauge; wireless nionitoring;
D O I
10.1016/j.msec.2005.09.001
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this work, screen-printing onto glass and polymer substrates was used to form capacitors with an active area of 2 x 3 mm(2). The dielectric was formed using a polymer paste with TiO2 as the functional ingredient. Devices prepared on glass substrates were tested as strain gauges. Their GF was measured to be 30. This is higher than the standard values (3 - 15) recorded for gauges based on oxide materials. It is thought that the higher sensitivity is a result of the preparation method and small crystallite size of the TiO2 powder. After quantifying the materials sensitivity, the sensors on polymer substrates were attached to planar and cylindrical surfaces. They were then incorporated into a wireless pressure measurement system, consisting of a small size interface circuit and a transmitter. The receiver outputs a voltage reading Corresponding to the sensor capacitance. Each device was placed in a liquid environment so that it could be exposed to hydrostatic pressure. A high sensitivity to pressure changes with low hysteresis was observed. It is thought that this system could be used to wirelessly monitor pressure changes in a variety of difficult to reach environments. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1077 / 1081
页数:5
相关论文
共 22 条
[1]  
[Anonymous], 1974, HDB THICK FILM HYBRI
[2]   Review of the potential of a wireless MEMS and TFT microsystems for the measurement of pressure in the GI tract [J].
Arshak, A ;
Arshak, K ;
Waldron, D ;
Morris, D ;
Korostynska, O ;
Jafer, E ;
Lyons, G .
MEDICAL ENGINEERING & PHYSICS, 2005, 27 (05) :347-356
[3]   AN ANALYSIS OF POLYMERIC THICK-FILM RESISTORS AS PRESSURE SENSORS [J].
ARSHAK, KI ;
RAY, AK ;
HOGARTH, CA ;
COLLINS, DG ;
ANSARI, F .
SENSORS AND ACTUATORS A-PHYSICAL, 1995, 49 (1-2) :41-45
[4]   NEW HIGH GAUGE-FACTOR THICK-FILM TRANSDUCER BASED ON A CAPACITOR CONFIGURATION [J].
ARSHAK, KI ;
COLLINS, D ;
ANSARI, F .
INTERNATIONAL JOURNAL OF ELECTRONICS, 1994, 77 (03) :387-399
[5]   Development of new capacitive strain sensors based on thick film polymer and cermet technologies [J].
Arshak, KI ;
McDonagh, D ;
Durcan, MA .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 79 (02) :102-114
[6]  
ARSHAK KI, 2004, E-POLYMERS, V61, P1
[7]  
BELAVIC D, 2000, IMAPS POLAND
[8]  
BERTAUX S, IN PRESS J EUR CERAM
[9]  
Brunette DM, 2001, TITANIUM MED, P1019
[10]   TEMPERATURE COEFFICIENT OF CAPACITANCE [J].
COCKBAIN, AG ;
HARROP, PJ .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1968, 1 (09) :1109-&