Novel method of displaying coronary CT angiography - Angiographic view

被引:22
作者
Jinzaki, Masahiro
Sato, Kozo
Tanami, Yutaka
Yamada, Minoru
Kuribayashi, Sachio
Anzai, Toshihisa
Asakura, Yasushi
Ogawa, Satoshi
机构
[1] Keio Univ, Sch Med, Dept Diagnost Radiol, Shinjuku Ku, Tokyo 1608582, Japan
[2] Keio Univ, Sch Med, Cardiovasc Imaging Lab, Shinjuku Ku, Tokyo 1608582, Japan
[3] Keio Univ, Sch Med, Cardiol Div, Shinjuku Ku, Tokyo 1608582, Japan
关键词
coronary artery; coronary computed tomography angiography; multidetector-row computed tomography;
D O I
10.1253/circj.70.1661
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background A method of displaying coronary computed tomography (CT) angiography, which enables evaluation of coronary artery disease (CAD) with fewer images and is understandable to the third person, is preferable. Methods and Results A maximum intensity projection image was created in which contrast media in the ventricles is eliminated, enabling an overview of CAD in a single 3-dimensional (D) image that can be rotated to be viewed at various angles and is easily understood by a third person. Conclusions A novel method of displaying coronary CT angiography in a single 3-D image has been developed and we believe it should become available for many workstations.
引用
收藏
页码:1661 / 1662
页数:2
相关论文
共 7 条
[1]   Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis [J].
Garcia, Mario J. ;
Lessick, Jonathan ;
Hoffmann, Martin H. K. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (04) :403-411
[2]   Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease - Patient-versus segment-based analysis [J].
Hoffmann, U ;
Moselewski, F ;
Cury, RC ;
Ferencik, M ;
Jang, IK ;
Diaz, LJ ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
CIRCULATION, 2004, 110 (17) :2638-2643
[3]  
Lichtenbelt Barthold, 1998, Introduction to Volume Rendering
[4]   Visualization of coronary artery anomalies and their anatomic course by contrast-enhanced electron beam tomography and three-dimensional reconstruction [J].
Ropers, D ;
Moshage, W ;
Daniel, WG ;
Jessl, J ;
Gottwik, M ;
Achenbach, S .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (02) :193-197
[5]   Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction [J].
Ropers, D ;
Baum, U ;
Pohle, K ;
Anders, K ;
Ulzheimer, S ;
Ohnesorge, B ;
Schlundt, C ;
Bautz, W ;
Daniel, WG ;
Achenbach, S .
CIRCULATION, 2003, 107 (05) :664-666
[6]   Efficacy of multislice computed tomography for the detection of acute coronary syndrome in the emergency department [J].
Sato, Y ;
Matsumoto, N ;
Ichikawa, M ;
Kunimasa, T ;
Iida, K ;
Yoda, S ;
Takayama, T ;
Uchiyama, T ;
Saito, S ;
Nagao, K ;
Tanaka, H ;
Inoue, F ;
Furuhashi, S ;
Takahashi, M ;
Koyama, Y .
CIRCULATION JOURNAL, 2005, 69 (09) :1047-1051
[7]   Evaluation of coronary artery lumen diameter with 16-slice multidetector-row computed tomography [J].
Yamada, M ;
Jinzaki, M ;
Kuribayashi, S ;
Sato, K ;
Tanami, Y ;
Yun, S ;
Sasaki, K .
CIRCULATION JOURNAL, 2005, 69 (10) :1230-1232