Infragenual cuff-compression reduces venous contamination in contrast-enhanced MR angiography of the calf

被引:16
作者
Bilecen, D
Schulte, AC
Bongartz, G
Heidecker, HG
Aschwanden, M
Jäger, KA
机构
[1] Univ Basel, Dept Diagnost Radiol, CH-4003 Basel, Switzerland
[2] Univ Basel, Dept Angiol, CH-4003 Basel, Switzerland
[3] Univ Freiburg, Dept Radiol, Sect Med Phys, D-7800 Freiburg, Germany
关键词
contrast-enhanced magnetic resonance angiography; venous contamination; peripheral arterial occlusive; disease; cuff-compression; infrapopliteal kinetics;
D O I
10.1002/jmri.20110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To reduce venous contamination at the calf level in three-dimensional contrast-enhanced MR angiography (CE-MRA) by applying continuous infragenual cuff-compression. Materials and Methods: Ten patients with clinically relevant peripheral arterial occlusive disease (PAOD) underwent dynamic three-dimensional CE-MRA of the calf. Six consecutive measurements were acquired with the first measurement serving as mask. Cuff-compression of 50 mmHg was attached below the knee. To allow intraindividual comparison, compression was applied unilaterally. The cuff was inflated three minutes before scanning and was continued throughout the MRA session. Venous contamination and arterial visualization scores were ranked using a five-point rating scale. Contrast-to-noise ratios (CNRs) of superficial enhancing calf-veins on the uncompressed and compressed calf sides were evaluated. An asymmetry index (AI) defined by CNRmeanuncompressed/CNRmeancompressed was introduced to describe the ratio in venous contrast agent supply between both sides quantitatively. Results: Three-dimensional CE-MRA of the calves demonstrated significantly lower superficial venous contamination scores (P<0.004) and clearly improved arterial visualization (P<0.009) on the compressed side. Additionally, AI values were larger than 1 (P<0.02), indicating a higher contrast agent supply in the superficial veins on the uncompressed side. Conclusion: Infragenual cuff-compression minimizes venous overlay in three-dimensional CE-MRA at calf level by reduction of contrast agent supply in the superficial veins.
引用
收藏
页码:347 / 351
页数:5
相关论文
共 21 条
[1]  
BERNSTEIN EF, 1993, VASCULAR DIAGNOSIS, P811
[2]   Optimized assessment of hand vascularization on contrast-enhanced MR angiography with a subsystolic continuous compression technique [J].
Bilecen, D ;
Aschwanden, M ;
Heidecker, HG ;
Bongartz, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (01) :180-182
[3]  
Bock M, 2000, MAGNET RESON MED, V43, P481, DOI 10.1002/(SICI)1522-2594(200003)43:3<481::AID-MRM21>3.0.CO
[4]  
2-N
[5]   Arterial first pass gadolinium-CM dynamics as a function of several intravenous saline flush and Gd volumes [J].
Boos, M ;
Scheffler, K ;
Haselhorst, R ;
Reese, E ;
Fröhlich, J ;
Bongartz, GM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :568-576
[6]   Suggested treatment protocol for improving patency of femoral-infrapopliteal cryopreserved saphenous vein allografts [J].
Buckley, CJ ;
Abernathy, S ;
Lee, SD ;
Arko, FR ;
Patterson, DE ;
Manning, LG .
JOURNAL OF VASCULAR SURGERY, 2000, 32 (04) :731-737
[7]   Time-resolved, undersampled projection reconstruction imaging for high-resolution CE-MRA of the distal runoff vessels [J].
Du, J ;
Carroll, TJ ;
Wagner, HJ ;
Vigen, K ;
Fain, SB ;
Block, WF ;
Korosec, FR ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) :516-522
[8]  
GUYTON A, 2000, LOCAL CONTROL BLOOD, P175
[9]   Peripheral vascular tree stenoses: Evaluation with moving-bed infusion-tracking MR angiography [J].
Ho, KYJAM ;
Leiner, T ;
de Haan, MW ;
Kessels, AGH ;
Kitslaar, PJEHM ;
van Engelshoven, JMA .
RADIOLOGY, 1998, 206 (03) :683-692
[10]   High-resolution gadolinium-enhanced 3D MRA of the infrapopliteal arteries: Lessons for improving bolus-chase peripheral MRA [J].
Hood, MN ;
Ho, VB ;
Foo, TKF ;
Marcos, HB ;
Hess, SL ;
Choyke, PL .
MAGNETIC RESONANCE IMAGING, 2002, 20 (07) :543-549