Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation

被引:870
作者
Wojtkowski, M [1 ]
Srinivasan, VJ
Ko, TH
Fujimoto, JG
Kowalczyk, A
Duker, JS
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[3] Nicholas Copernicus Univ, Inst Phys, PL-87100 Torun, Poland
[4] Tufts Univ New England Med Ctr, New England Eye Ctr, Boston, MA USA
来源
OPTICS EXPRESS | 2004年 / 12卷 / 11期
关键词
D O I
10.1364/OPEX.12.002404
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Ultrahigh-resolution optical coherence tomography uses broadband light sources to achieve axial image resolutions on the few micron scale. Fourier domain detection methods enable more than an order of magnitude increase in imaging speed and sensitivity, thus overcoming the sensitivity limitations inherent in ultrahigh-resolution OCT using standard time domain detection. Fourier domain methods also provide direct access to the spectrum of the optical signal. This enables automatic numerical dispersion compensation, a key factor in achieving ultrahigh image resolutions. We present ultrahigh-resolution, high-speed Fourier domain OCT imaging with an axial resolution of 2.1 mum in tissue and 16,000 axial scans per second at 1024 pixels per axial scan. Ultrahigh-resolution spectral domain OCT is shown to provide a similar to100x increase in imaging speed when compared to ultrahigh-resolution time domain OCT. In vivo imaging of the human retina is demonstrated. We also present a general technique for automatic numerical dispersion compensation, which is applicable to spectral domain as well as swept source embodiments of Fourier domain OCT. (C) 2004 Optical Society of America.
引用
收藏
页码:2404 / 2422
页数:19
相关论文
共 44 条
[1]   Compact, broad-bandwidth fiber laser for sub-2-μm axial resolution optical coherence tomography in the 1300-nm wavelength region [J].
Bizheva, K ;
Povazay, B ;
Hermann, B ;
Sattmann, H ;
Drexler, W ;
Mei, M ;
Holzwarth, R ;
Hoelzenbein, T ;
Wacheck, V ;
Pehamberger, H .
OPTICS LETTERS, 2003, 28 (09) :707-709
[2]   HIGH-RESOLUTION OPTICAL COHERENCE TOMOGRAPHIC IMAGING USING A MODE-LOCKED TI-AL2O3 LASER SOURCE [J].
BOUMA, B ;
TEARNEY, GJ ;
BOPPART, SA ;
HEE, MR ;
BREZINSKI, ME ;
FUJIMOTO, JG .
OPTICS LETTERS, 1995, 20 (13) :1486-1488
[3]   Ultrahigh resolution real time OCT imaging using a compact femtosecond Nd:Glass laser and nonlinear fiber [J].
Bourquin, S ;
Aguirre, AD ;
Hartl, I ;
Hsiung, P ;
Ko, TH ;
Fujimoto, JG ;
Birks, TA ;
Wadsworth, WJ ;
Bünting, U ;
Kopf, D .
OPTICS EXPRESS, 2003, 11 (24) :3290-3297
[4]   Optical coherence tomography using a frequency-tunable optical source [J].
Chinn, SR ;
Swanson, EA ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (05) :340-342
[5]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[6]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[7]   Stable carrier generation and phase-resolved digital data processing in optical coherence tomography [J].
de Boer, JF ;
Saxer, CE ;
Nelson, JS .
APPLIED OPTICS, 2001, 40 (31) :5787-5790
[8]   In vivo ultrahigh-resolution optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Kärtner, FX ;
Pitris, C ;
Boppart, SA ;
Li, XD ;
Ippen, EP ;
Fujimoto, JG .
OPTICS LETTERS, 1999, 24 (17) :1221-1223
[9]   Enhanced visualization of macular pathology with the use of ultrahigh-resolution optical coherence tomography [J].
Drexler, W ;
Sattmarin, H ;
Hermann, B ;
Ko, TH ;
Stur, M ;
Unterhuber, A ;
Scholda, C ;
Findl, O ;
Wirtitsch, M ;
Fujimoto, JG ;
Fercher, AF .
ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (05) :695-706
[10]   Ultrahigh-resolution ophthalmic optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Ghanta, RK ;
Kärtner, FX ;
Schuman, JS ;
Fujimoto, JG .
NATURE MEDICINE, 2001, 7 (04) :502-507