Studies on glucose biosensors based on nonmediated and mediated electrochemical oxidation of reduced glucose oxidase encapsulated within organically modified sol-gel glasses

被引:1
作者
Pandey, PC [1 ]
Upadhyay, S [1 ]
Pathak, HC [1 ]
Tiwari, I [1 ]
Tripathi, VS [1 ]
机构
[1] Banaras Hindu Univ, Dept Chem, Varanasi 221005, Uttar Pradesh, India
关键词
organically modified sol-gel glass; voltammetry; amperometry; glucose biosensor; mediated bioelectrochemistry;
D O I
10.1002/(SICI)1521-4109(199911)11:17<1251::AID-ELAN1251>3.0.CO;2-M
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, organically modified sol-gel glass electrode is reported using 3-aminopropyltriethoxy silane and 2-(3,4-epoxycyclohexyl)-ethyltrimethoxy silane as sol-gel precursors for the construction of electrochemical biosensors. Four different systems of new sol-gel grass modified glucose electrodes are made in acidic medium having common sol-gel precursors and: 1) glucose oxidase, 2) glucose oxidase along with polyethylene glycol, 3) glucose oxidase and graphite powder, and 4) glucose oxidase along with polyethylene glycol and graphite powder. Both nonmediated and mediated electrochemical regeneration of immobilized glucose oxidase within sol-gel glasses are studied in these four systems. The nonmediated regeneration is achieved in the presence of oxygen as electron donor whereas mediated regeneration involves soluble ferrocene monocarboxylic acid as electron donor in each system. The electrochemical performance of sol-gel glass based biosensors is compared on the basis of cyclic voltammetry and amperometry. This leads to the observations: i) all four systems reach a diffusion limited condition associated with the transport of soluble ferrocene monocarboxylic acid as well as for dissolved oxygen within the sol-gel matrix, ii) the relative rate of diffusion of these analytes increases from system I to system 4, iii) both nonmediated and mediated amperometric responses at suitable potentials are based on the oxidation of H2O2 and enzymatically reduced soluble ferrocene with relatively amplified electrochemical signal of system 4. Data on the reduction of oxygen at conventional graphite disk electrode and at typical sol-gel glass modified electrode are reported.
引用
收藏
页码:1251 / 1258
页数:8
相关论文
共 37 条
[21]  
Pandey PC, 1999, ELECTROANAL, V11, P950, DOI 10.1002/(SICI)1521-4109(199909)11:13<950::AID-ELAN950>3.0.CO
[22]  
2-N
[23]   APPLICATION OF PHOTOCHEMICAL-REACTION IN ELECTROCHEMICAL DETECTION OF DNA INTERCALATION [J].
PANDEY, PC ;
WEETALL, HH .
ANALYTICAL CHEMISTRY, 1994, 66 (08) :1236-1241
[24]  
Pandey PC, 1999, ELECTROANAL, V11, P59, DOI 10.1002/(SICI)1521-4109(199901)11:1<59::AID-ELAN59>3.0.CO
[25]  
2-P
[26]   Polyindole modified potassium ion sensor using dibenzo-18-crown-6 mediated PVC matrix membrane [J].
Pandey, PC ;
Prakash, R .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 46 (01) :61-65
[27]   Reversal in the kinetics of the M state decay of D96N bacteriorhodopsin: Probing of enzyme catalyzed reactions [J].
Pandey, PC ;
Singh, S ;
Upadhyay, B ;
Weetall, HH ;
Chen, PK .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 36 (1-3) :470-474
[28]  
PANKRATOV B, 1993, J ELECTROANAL CHEM, V393, P35
[29]   NEW MATERIALS FOR CONTACT-LENSES PREPARED FROM SI-ALKOXIDES AND TI-ALKOXIDES BY THE SOL-GEL PROCESS [J].
PHILIPP, G ;
SCHMIDT, H .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 1984, 63 (1-2) :283-292
[30]   Inert metal-modified, composite ceramic-carbon, amperometric biosensors: Renewable, controlled reactive layer [J].
Sampath, S ;
Lev, O .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2015-2021