Battery-powered miniature bipotentiostats for amperometric biosensors

被引:3
作者
Quinn, CP [1 ]
Wagner, JG [1 ]
Heller, A [1 ]
Yarnitzky, N [1 ]
机构
[1] TECHNION ISRAEL INST TECHNOL, DEPT CHEM, IL-32000 HAIFA, ISRAEL
关键词
D O I
10.1080/10739149608001212
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The design and characterization of two miniature bipotentiostats for use with amperometric biosensors is described. The bipotentiostats are powered by 9V batteries and have counter electrode potential swings of +/- 1.5 V and +/- 3.0 V. respectively. In the first, a voltage signal, proportional to the current generated by the sensor, is transferred to a data logger. In the second, the output signal is transmitted to a personal computer through an opto-coupler by pulse width modulation so as to electrically isolate the system in or on the body from the external AC line. The devices accurately measure currents in the nA range and their output signals are stable for over 100 h. They are suitable for use in both in vitro and in vivo studies requiring accurate amperometry.
引用
收藏
页码:263 / 275
页数:13
相关论文
共 16 条
[1]   DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING [J].
BINDRA, DS ;
ZHANG, YN ;
WILSON, GS ;
STERNBERG, R ;
THEVENOT, DR ;
MOATTI, D ;
REACH, G .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1692-1696
[2]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[3]  
CSOREGI E, 1994, ANAL CHEM, V66, P3131
[4]   DEVELOPMENT OF CHOLINE AND ACETYLCHOLINE PT MICROELECTRODES [J].
HUANG, ZX ;
VILLARTASNOW, R ;
LUBRANO, GJ ;
GUILBAULT, GG .
ANALYTICAL BIOCHEMISTRY, 1993, 215 (01) :31-37
[5]   INVIVO EVALUATION OF AN ELECTROENZYMATIC GLUCOSE SENSOR IMPLANTED IN SUBCUTANEOUS TISSUE [J].
JOHNSON, KW ;
MASTROTOTARO, JJ ;
HOWEY, DC ;
BRUNELLE, RL ;
BURDENBRADY, PL ;
BRYAN, NA ;
ANDREW, CC ;
ROWE, HM ;
ALLEN, DJ ;
NOFFKE, BW ;
MCMAHAN, WC ;
MORFF, RJ ;
LIPSON, D ;
NEVIN, RS .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (10) :709-714
[6]   MICROBIOSENSORS FOR ACETYLCHOLINE AND GLUCOSE [J].
KARUBE, I ;
YOKOYAMA, K ;
TAMIYA, E .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (3-4) :219-228
[7]   THE FUNCTION OF A HYDROGEN PEROXIDE-DETECTING ELECTROENZYMATIC GLUCOSE ELECTRODE IS MARKEDLY IMPAIRED IN HUMAN SUB-CUTANEOUS TISSUE AND PLASMA [J].
KERNER, W ;
KIWIT, M ;
LINKE, B ;
KECK, FS ;
ZIER, H ;
PFEIFFER, EF .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (9-10) :473-482
[8]   EXTRACORPOREAL DETERMINATION OF GLUCOSE, LACTATE AND POTASSIUM WITH ELECTROCHEMICAL BIOSENSORS [J].
MASCINI, M ;
PALLESCHI, G ;
MOSCONE, D ;
BERNARDI, L .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (12) :1377-1383
[9]   ON LINE CONTINUOUS MONITORING OF BLOOD LACTATE IN MEN BY A WEARABLE DEVICE BASED UPON AN ENZYMATIC AMPEROMETRIC LACTATE SENSOR [J].
MEYERHOFF, C ;
BISCHOF, F ;
MENNEL, FJ ;
STERNBERG, F ;
BICAN, J ;
PFEIFFER, EF .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (9-10) :409-414
[10]   LACTATE AND GLUCOSE ELECTROCHEMICAL BIOSENSORS FOR THE EVALUATION OF THE AEROBIC AND ANAEROBIC THRESHOLD IN RUNNERS [J].
PALLESCHI, G ;
MASCINI, M ;
BERNARDI, L ;
ZEPPILLI, P .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (03) :B25-B28