Implant design affects knee arthroplasty kinematics during stair-stepping

被引:114
作者
Banks, SA
Hodge, WA
机构
[1] Biomot Fdn, W Palm Beach, FL 33401 USA
[2] Palm Beach Orthopaed Inst, W Palm Beach, FL USA
关键词
D O I
10.1097/01.blo.0000138956.04316.ac
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Knee implant motions have a direct influence on patient function and implant longevity. The purpose of this study was to determine if there were consistent differences in knee motions among three groups of knee implants. Two hundred thirteen knees in 173 patients, with 25 implant designs, were studied using fluoroscopy during stair-stepping. All knee implants were assigned to one of three groups based on the design: fixed-bearing posterior-stabilized, fixed-bearing posterior cruciate-retaining, and mobile-bearing. All types of implants had the same pattern of internal/external rotations, but different designs had different anteroposterior translations. Seventy-five percent of posterior-stabilized knee implants had a medial center of rotation, indicating posterior femoral translation with flexion. Sixty-three percent of cruciate-retaining fixed-bearing knee implants had a lateral center of rotation. Eighty-six percent of mobile-bearing knee implants had a lateral center of rotation, indicating anterior femoral translation with flexion. Knee motion in patients with successful total knee arthroplasties is related directly to the constraints of the implant design.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 38 条
[21]   Radiographic analysis of low contact stress meniscal bearing total knee replacements [J].
Hartford, JM ;
Banit, D ;
Hall, K ;
Kaufer, H .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (02) :229-234
[22]  
Ishii Y, 1999, CLIN ORTHOP RELAT R, P181
[23]   Weight-bearing knee kinematics in subjects with two types of anterior cruciate ligament reconstructions [J].
Kanisawa, I ;
Banks, AZ ;
Banks, SA ;
Moriya, H ;
Tsuchiya, A .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (01) :16-22
[24]  
Karrholm J, 1994, Knee Surg Sports Traumatol Arthrosc, V2, P50, DOI 10.1007/BF01552655
[25]  
LEWIS P, 1994, CLIN ORTHOP RELAT R, P11
[26]   The effect of total knee arthroplasty design on extensor mechanism function [J].
Mahoney, OM ;
McClung, CD ;
dela Rosa, MA ;
Schmalzried, TP .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :416-421
[27]   ABNORMAL KINEMATICS OF THE ARTIFICIAL KNEE - ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS OF 10 MILLER-GALANTE AND 5 NEW-JERSEY LCS KNEES [J].
NILSSON, KG ;
KARRHOLM, J ;
GADEGAARD, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (05) :440-446
[28]  
NOBLE PC, 2001, T ORTHOP RES SOC, V47, P1102
[29]   Observations of femoral rollback in cruciate-retaining knee arthroplasty [J].
Nozaki, H ;
Banks, SA ;
Suguro, T ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) :308-314
[30]  
Ritter M A, 1988, J Arthroplasty, V3, P323, DOI 10.1016/S0883-5403(88)80032-9