Using Laser-Induced Acoustic Desorption/Electrospray Ionization Mass Spectrometry To Characterize Small Organic and Large Biological Compounds in the Solid State and in Solution Under Ambient Conditions

被引:69
作者
Cheng, Sy-Chyi [1 ]
Cheng, Tain-Lu [2 ,3 ]
Chang, Hui-Chiu [3 ,4 ]
Shiea, Jentaie [1 ,3 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 804, Taiwan
[2] Kaohsiung Med Univ, Inst Med, Kaohsiung, Taiwan
[3] Natl Sun Yat Sen Univ, Kaohsiung Med Univ, Joint Res Ctr, Kaohsiung 804, Taiwan
[4] Kaohsiung Med Univ, Fac Biomed Sci & Environm Biol, Kaohsiung, Taiwan
关键词
DESORPTION; MOLECULES;
D O I
10.1021/ac800896y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have coupled laser-induced acoustic desorption (LIAD) with electrospray ionization (ESI) mass spectrometry (LIAD/ESI/MS) to characterize molecules in the solid state and in solution under ambient conditions. To perform an LIAD/ESI analysis, the sample droplet is deposited on the surface of a thin aluminum foil by a micropipette; the rear side of the foil with the sample spot is then irradiated with a pulse from a Nd:YAG IR laser. The resulting shockwave and heat cause the sample on the rear side to change from the condensed phase to the gas phase. The desorbed species then move upward to enter an ESI plume to react with charged solvent species (methanol- and water-related ions and droplets), forming singly or multiply charged analyte ions. A quadrupole/time-of-flight (Q-TOF) mass analyzer attached to the LIAD/ESI source detects the analyte ions to obtain an ESI-like mass spectrum. Both small organic and large biological compounds (including amino acids, peptides, and proteins) were successfully ionized and detected by the LIAD/ESI/MS system. Although native and denatured myoglobin ions were both detected from a liquid sample solution, only the denatured myoglobin ions were detected from a dried sample.
引用
收藏
页码:868 / 874
页数:7
相关论文
共 29 条
[1]   Analysis of polyethylene by using cyclopentadienyl cobalt chemical ionization combined with laser-induced acoustic desorption/Fourier transform ion cyclotron resonance mass spectrometry [J].
Campbell, JL ;
Fiddler, MN ;
Crawford, KE ;
Gqamana, PP ;
Kenttämaa, HI .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4020-4026
[2]   Analysis of saturated hydrocarbons by using chemical ionization combined with laser-induced acoustic desorption/Fourier transform ion cyclotron resonance mass spectrometry [J].
Campbell, JL ;
Crawford, KE ;
Kenttämaa, HI .
ANALYTICAL CHEMISTRY, 2004, 76 (04) :959-963
[3]   Detecting large biomolecules from high-salt solutions by fused-droplet electrospray ionization mass spectrometry [J].
Chang, DY ;
Lee, CC ;
Shiea, J .
ANALYTICAL CHEMISTRY, 2002, 74 (11) :2465-2469
[4]   Laser-induced acoustic desorption/Fourier transform ion cyclotron resonance mass spectrometry for petroleum distillate analysis [J].
Crawford, KE ;
Campbell, JL ;
Fiddler, MN ;
Duan, P ;
Qian, K ;
Gorbaty, ML ;
Kenttämaa, HI .
ANALYTICAL CHEMISTRY, 2005, 77 (24) :7916-7923
[5]   Analysis of base oil fractions by ClMn(H2O)+ chemical ionization combined with laser-induced acoustic desorption/Fourier transform ion cyclotron resonance mass spectrometry [J].
Duan, Penggao ;
Qian, Kuangnan ;
Habicht, Steven C. ;
Pinkston, David S. ;
Fu, Mingkun ;
Kenttamaa, Hilkka I. .
ANALYTICAL CHEMISTRY, 2008, 80 (06) :1847-1853
[6]   Laser-induced acoustic desorption of electrons and ions [J].
Golovlev, VV ;
Allman, SL ;
Garrett, WR ;
Chen, CH .
APPLIED PHYSICS LETTERS, 1997, 71 (06) :852-854
[7]   Laser-induced acoustic desorption [J].
Golovlev, VV ;
Allman, SL ;
Garrett, WR ;
Taranenko, NI ;
Chen, CH .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 169 :69-78
[8]   A multiple channel electrospray source used to detect highly reactive ketenes from a flow pyrolyzer [J].
Hong, CM ;
Tsai, FC ;
Shiea, J .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1175-1178
[9]   Characterization of synthetic polymers by electrospray-assisted pyrolysis ionization-mass spectrometry [J].
Hsu, HJ ;
Kuo, TL ;
Wu, SH ;
Oung, JH ;
Shiea, J .
ANALYTICAL CHEMISTRY, 2005, 77 (23) :7744-7749
[10]   Direct protein detection from biological media through electrospray-assisted laser desorption ionization/mass spectrometry [J].
Huang, MZ ;
Hsu, HJ ;
Lee, LY ;
Jeng, JY ;
Shiea, JT .
JOURNAL OF PROTEOME RESEARCH, 2006, 5 (05) :1107-1116