Biosensors for Whole-Cell Bacterial Detection

被引:470
作者
Ahmed, Asif [1 ]
Rushworth, Jo V. [1 ]
Hirst, Natalie A. [1 ]
Millner, Paul A. [1 ]
机构
[1] Univ Leeds, Fac Biol Sci, Sch Biomed Sci, Leeds, W Yorkshire, England
关键词
SURFACE-PLASMON RESONANCE; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ESCHERICHIA-COLI O157H7; LABEL-FREE DETECTION; HIGHLY SENSITIVE DETECTION; 16S RIBOSOMAL-RNA; REAL-TIME PCR; IMPEDIMETRIC IMMUNOSENSOR; RAPID DETECTION; SALMONELLA-TYPHIMURIUM;
D O I
10.1128/CMR.00120-13
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Bacterial pathogens are important targets for detection and identification in medicine, food safety, public health, and security. Bacterial infection is a common cause of morbidity and mortality worldwide. In spite of the availability of antibiotics, these infections are often misdiagnosed or there is an unacceptable delay in diagnosis. Current methods of bacterial detection rely upon laboratory-based techniques such as cell culture, microscopic analysis, and biochemical assays. These procedures are time-consuming and costly and require specialist equipment and trained users. Portable stand-alone biosensors can facilitate rapid detection and diagnosis at the point of care. Biosensors will be particularly useful where a clear diagnosis informs treatment, in critical illness (e.g., meningitis) or to prevent further disease spread (e.g., in case of food-borne pathogens or sexually transmitted diseases). Detection of bacteria is also becoming increasingly important in anti-bioterrorism measures (e.g., anthrax detection). In this review, we discuss recent progress in the use of biosensors for the detection of whole bacterial cells for sensitive and earlier identification of bacteria without the need for sample processing. There is a particular focus on electrochemical biosensors, especially impedance-based systems, as these present key advantages in terms of ease of miniaturization, lack of reagents, sensitivity, and low cost.
引用
收藏
页码:631 / 646
页数:16
相关论文
共 119 条
  • [1] scFv Antibody: Principles and Clinical Application
    Ahmad, Zuhaida Asra
    Yeap, Swee Keong
    Ali, Abdul Manaf
    Ho, Wan Yong
    Alitheen, Noorjahan Banu Mohamed
    Hamid, Muhajir
    [J]. CLINICAL & DEVELOPMENTAL IMMUNOLOGY, 2012,
  • [2] PCR-less DNA co-polymerization detection of Shiga like toxin 1 (stx1) in Escherichia coli O157:H7
    Anderson, Michael J.
    Miller, Hanna R.
    Alocilja, Evangelyn C.
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 42 : 581 - 585
  • [3] Comparative advantages of mechanical biosensors
    Arlett, J. L.
    Myers, E. B.
    Roukes, M. L.
    [J]. NATURE NANOTECHNOLOGY, 2011, 6 (04) : 203 - 215
  • [4] Surface plasmon resonance immunosensor for bacteria detection
    Baccar, H.
    Mejri, M. B.
    Hafaiedh, I.
    Ktari, T.
    Aouni, M.
    Abdelghani, A.
    [J]. TALANTA, 2010, 82 (02) : 810 - 814
  • [5] Bamberger DM, 2010, AM FAM PHYSICIAN, V82, P1491
  • [6] Multiplex Real-Time PCR for Detection of Campylobacter, Salmonella, and Shigella
    Barletta, F.
    Mercado, E. H.
    Lluque, A.
    Ruiz, J.
    Cleary, T. G.
    Ochoa, T. J.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (09) : 2822 - 2829
  • [7] Highly sensitive detection of pathogen Escherichia coli O157:H7 by electrochemical impedance spectroscopy
    Barreiros dos Santos, M.
    Agusil, J. P.
    Prieto-Simon, B.
    Sporer, C.
    Teixeira, V.
    Samitier, J.
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 45 : 174 - 180
  • [8] Berggren C, 2001, ELECTROANAL, V13, P173, DOI 10.1002/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO
  • [9] 2-B
  • [10] The Changing Landscape of Diagnostic Services for Tuberculosis Preface
    Boehme, Catharina C.
    Saacks, Sharon
    O'Brien, Richard J.
    [J]. SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 34 (01) : 17 - 31