Comparison of synchrotron radiation and conventional x-ray microcomputed tomography for assessing trabecular bone microarchitecture of human femoral heads

被引:62
作者
Chappard, Christine
Basillais, Armelle
Benhamou, Laurent
Bonassie, Alexandra
Brunet-Imbault, Barbara
Bonnet, Nicolas
Peyrin, Francoise
机构
[1] INSERM, U 658, F-45000 Orleans, France
[2] CREATIS, ESRF, F-38043 Grenoble, France
关键词
three-dimensional microtomography; synchrotron radiation; bone trabecular pattern;
D O I
10.1118/1.2256069
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Microcomputed tomography (mu CT) produces three-dimensional (3D) images of trabecular bone. We compared conventional mu CT (C mu CT) with a polychromatic x-ray cone beam to synchrotron radiation (SR) ACT with a monochromatic parallel beam for assessing trabecular bone microarchitecture of 14 subchondral femoral head specimens from patients with osteoarthritis (n = 10) or osteoporosis (n = 4). SR mu CT images with a voxel size of 10.13 Am were reconstructed from 900 2D radiographic projections (angular step, 0.2 degrees). C mu CT images with a voxel size of 10.77 Am were reconstructed from 205, 413, and 825 projections obtained using angular steps of 0.9 degrees, 0.45 degrees, and 0.23 degrees, respectively. A single threshold was used to binarize the images. We computed bone volume/tissue volume (BV/TV), bone surface/bone volume (BS/BV), trabecular number (Tb.N), trabecular thickness (Tb.Th and Tb.Th*), trabecular spacing (Tb.Sp), degree of anisotropy (DA), and Euler density. With the 0.9 degrees angular step, all C mu CT values were significantly different from SR mu CT values. With the 0.23 degrees and 0.45 degrees rotation steps, BV/TV, Tb.Th, and BS/BV by C mu CT differed significantly from the values by SR mu CT. The error due to slice matching (visual site matching 10 slices) was within 1% for most parameters. Compared to SRACT, BV/TV, Tb.Sp, and Tb.Th by C mu CT were underestimated, whereas Tb.N and Tb.Th* were overestimated. A Bland and Altman plot showed no bias for Tb.N or DA. Bias was -0.8 +/- 1.0%, +5.0 +/- 1.1 mu m, -5.9 +/- 6.3 mu m, and -5.7 +/- 29.1 mu m for BV/TV, Th.Th*, Tb.Th, and Tb.Sp, respectively, and the differences did not vary over the range of values. Although systematic differences were noted between SR mu CT and CACT values, correlations between the techniques were high and the differences would probably not change the discrimination between study groups. CACT provides a reliable 3D assessment of human defatted bone when working at the 0.23 degrees or 0.45 degrees rotation step; the 0.9 degrees rotation step may be insufficiently accurate for morphological bone analysis. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:3568 / 3577
页数:10
相关论文
共 46 条
[1]   Ex vivo assessment of trabecular bone structure from three-dimensional projection reconstruction MR micro-images [J].
Accardo, A ;
Candido, G ;
Jellús, V ;
Toffanin, R ;
Vittur, F .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (08) :967-977
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   3D COMPUTED X-RAY TOMOGRAPHY OF HUMAN CANCELLOUS BONE AT 8 MU-M SPATIAL AND 10(-4) ENERGY RESOLUTION [J].
BONSE, U ;
BUSCH, F ;
GUNNEWIG, O ;
BECKMANN, F ;
PAHL, R ;
DELLING, G ;
HAHN, M ;
GRAEFF, W .
BONE AND MINERAL, 1994, 25 (01) :25-38
[4]   Risedronate preserves trabecular architecture and increases bone strength in vertebra of ovariectomized minipigs as measured by three-dimensional microcomputed tomography [J].
Borah, B ;
Dufresne, TE ;
Chmielewski, PA ;
Gross, GJ ;
Prenger, MC ;
Phipps, RJ .
JOURNAL OF BONE AND MINERAL RESEARCH, 2002, 17 (07) :1139-1147
[5]  
CHUNG HW, 1995, J BONE MINER RES, V10, P1452
[6]   Effects of daily treatment with parathyroid hormone on bone microarchitecture and turnover in patients with osteoporosis:: A paired biopsy study [J].
Dempster, DW ;
Cosman, F ;
Kurland, ES ;
Zhou, H ;
Nieves, J ;
Woelfert, L ;
Shane, E ;
Plavetic, K ;
Müller, R ;
Bilezikian, J ;
Lindsay, R .
JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 (10) :1846-1853
[7]   Accuracy of cancellous bone volume fraction measured by micro-CT scanning [J].
Ding, M ;
Odgaard, A ;
Hvid, I .
JOURNAL OF BIOMECHANICS, 1999, 32 (03) :323-326
[8]   Risedronate preserves bone architecture in early postmenopausal women in 1 year as measured by three-dimensional microcomputed tomography [J].
Dufresne, TE ;
Chmielewski, PA ;
Manhart, MD ;
Johnson, TD ;
Borah, B .
CALCIFIED TISSUE INTERNATIONAL, 2003, 73 (05) :423-432
[9]   Segmentation of cancellous bone from high-resolution computed tomography images: Influence on trablecular bone measurements [J].
Elmoutaouakkil, A ;
Peyrin, F ;
Elkafi, J ;
Laval-Jeantet, AM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (04) :354-362
[10]   HIGH SPATIAL-RESOLUTION IMAGING OF BONE-MINERAL USING COMPUTED MICROTOMOGRAPHY - COMPARISON WITH MICRORADIOGRAPHY AND UNDECALCIFIED HISTOLOGIC SECTIONS [J].
ENGELKE, K ;
GRAEFF, W ;
MEISS, L ;
HAHN, M ;
DELLING, G .
INVESTIGATIVE RADIOLOGY, 1993, 28 (04) :341-349