Direct comparison of an intravascular and an extracellular contrast agent for quantification of myocardial perfusion

被引:83
作者
Jerosch-Herold, M [1 ]
Wilke, N [1 ]
Wang, Y [1 ]
Gong, GR [1 ]
Mansoor, AM [1 ]
Huang, H [1 ]
Gurchumelidze, S [1 ]
Stillman, AE [1 ]
机构
[1] Univ Minnesota, Dept Radiol, Minneapolis, MN 55455 USA
来源
INTERNATIONAL JOURNAL OF CARDIAC IMAGING | 1999年 / 15卷 / 06期
关键词
D O I
10.1023/A:1006368619112
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A direct comparison of extracellular and intravascular contrast agents for the assessment of myocardial perfusion was carried out in a porcine model (N = 5) with a flow-limiting occluder on the left anterior descending coronary artery. Rapid imaging during the first pass of an extracellular or intravascular contrast agent with a saturation-recovery-prepared TurboFLASH sequence showed comparable peak contrast-to-noise enhancements in myocardial tissue regions with flows averaging 1.1 +/- 0.2 at baseline to 4.8 +/- 0.6 ml/min/g during hyperemia. The coefficient of variation between the MR estimates of blood flow with Gadomer-17 and the microsphere blood flow measurements was 11 +/- 11, while the corresponding coefficient of variation for blood flow estimates with the extracellular CA was 23 +/- 11. Blood volume differences between rest and hyperemia observed with the intravascular tracer were significant (V-vasc(rest) = 0.078 +/- 0.013 ml/g, versus V-vasc(hyperemia) = 0.102 +/- 0.019 ml/g; p < 0.05). The effects of water exchange were minimized through the choice of pulse sequence parameters to provide blood volume estimates consistent with the changes expected between rest and hyperemia. This study represents the first application of multiple indicators in first pass imaging studies for the assessment of myocardial perfusion. The use of an intravascular instead of an extracellular contrast agent allows a reduction of the degrees of freedom for modeling tissue residue curves and results in improved accuracy of blood flow estimates.
引用
收藏
页码:453 / 464
页数:12
相关论文
共 24 条
[21]   DENDRIMER-BASED METAL-CHELATES - A NEW CLASS OF MAGNETIC-RESONANCE-IMAGING CONTRAST AGENTS [J].
WIENER, EC ;
BRECHBIEL, MW ;
BROTHERS, H ;
MAGIN, RL ;
GANSOW, OA ;
TOMALIA, DA ;
LAUTERBUR, PC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) :1-8
[22]   Myocardial perfusion reserve: Assessment with multisection, quantitative, first-pass MR imaging [J].
Wilke, N ;
JeroschHerold, M ;
Wang, Y ;
Huang, YM ;
Christensen, BV ;
Stillman, AE ;
Ugurbil, K ;
McDonald, K ;
Wilson, RF .
RADIOLOGY, 1997, 204 (02) :373-384
[23]   REGIONAL MYOCARDIAL BLOOD-VOLUME AND FLOW - FIRST-PASS MR-IMAGING WITH POLYLYSINE-GD-DTPA [J].
WILKE, N ;
KROLL, K ;
MERKLE, H ;
WANG, Y ;
ISHIBASHI, Y ;
XU, Y ;
ZHANG, JN ;
JEROSCHHEROLD, M ;
MUHLER, A ;
STILLMAN, AE ;
BASSINGTHWAIGHTE, JB ;
BACHE, R ;
UGURBIL, K .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (02) :227-237
[24]   CONTRAST-ENHANCED 1ST PASS MYOCARDIAL PERFUSION IMAGING - CORRELATION BETWEEN MYOCARDIAL BLOOD-FLOW IN DOGS AT REST AND DURING HYPEREMIA [J].
WILKE, N ;
SIMM, C ;
ZHANG, J ;
ELLERMANN, J ;
YA, X ;
MERKLE, H ;
PATH, G ;
LUDEMANN, H ;
BACHE, RJ ;
UGURBIL, K .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (04) :485-497