Red diode laser induced fluorescence detection with a confocal microscope on a microchip for capillary electrophoresis

被引:109
作者
Jiang, GF
Attiya, S
Ocvirk, G
Lee, WE
Harrison, DJ
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
[2] Def Res Estab Suffield, Medicine Hat, AB T1A 8K6, Canada
关键词
microfluidics; affinity capillary electrophoresis; capillary zone electrophoresis; immunoassay; simulant; ovalbumin;
D O I
10.1016/S0956-5663(99)00056-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A highly sensitive laser induced fluorescence (LIF) detection system based on a 635 nm laser diode and cyanine-5 (Cy-5) dye, is described for use with a planar, microfluidic, capillary electrophoresis (CE) chip. The CE-chip is able to determine a protein biological threat agent simulant, ovalbumin (Ov), by performing an immunoassay separation of Cy-5 labeled anti-ovalbumin from its complex with Ov, in under 30 s. A confocal, epiluminescent detection system utilizing a photomultiplier tube gave optimum results with a 400 mu m pinhole, an Omega 682DF22 emission filter, a 645DRLP02 dichroic mirror, a 634.54 +/- 5 nm excitation filter, and a Power Technology ACM08 635 MI laser operated at 11.2 mW. Using this detector, a microchip CE device with a separation efficiency of 42 000 plates and an etch depth of 20 mu m, gave a concentration detection limit of 9 pM Cy-5. This limit corresponds to the determination of 4560 injected molecules and detection of 900 of these molecules, given a probe volume of 1.6 pi and a probing efficiency of 20%. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:861 / 869
页数:9
相关论文
共 31 条
[21]   PLANAR CHIPS TECHNOLOGY FOR MINIATURIZATION AND INTEGRATION OF SEPARATION TECHNIQUES INTO MONITORING SYSTEMS - CAPILLARY ELECTROPHORESIS ON A CHIP [J].
MANZ, A ;
HARRISON, DJ ;
VERPOORTE, EMJ ;
FETTINGER, JC ;
PAULUS, A ;
LUDI, H ;
WIDMER, HM .
JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2) :253-258
[22]   CAPILLARY ISOTACHOPHORESIS WITH CONCENTRATION GRADIENT DETECTION [J].
MCDONNELL, T ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1884-1889
[23]   A displacement flow immunosensor for explosive detection using microcapillaries [J].
Narang, U ;
Gauger, PR ;
Ligler, FS .
ANALYTICAL CHEMISTRY, 1997, 69 (14) :2779-2785
[24]   Optimization of confocal epifluorescence microscopy for microchip-based miniaturized total analysis systems [J].
Ocvirk, G ;
Tang, T ;
Harrison, DJ .
ANALYST, 1998, 123 (07) :1429-1434
[25]   Capillary electrophoresis based immunoassays: A critical review [J].
Schmalzing, D ;
Nashabeh, W .
ELECTROPHORESIS, 1997, 18 (12-13) :2184-2193
[26]   PLANAR GLASS CHIPS FOR CAPILLARY ELECTROPHORESIS - REPETITIVE SAMPLE INJECTION, QUANTITATION, AND SEPARATION EFFICIENCY [J].
SEILER, K ;
HARRISON, DJ ;
MANZ, A .
ANALYTICAL CHEMISTRY, 1993, 65 (10) :1481-1488
[27]   DETECTION OF TNT IN WATER USING AN EVANESCENT-WAVE FIBEROPTIC BIOSENSOR [J].
SHRIVERLAKE, LC ;
BRESLIN, KA ;
CHARLES, PT ;
CONRAD, DW ;
GOLDEN, JP ;
LIGLER, FS .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2431-2435
[28]   On line competitive immunoassay for insulin based on capillary electrophoresis with laser induced fluorescence detection [J].
Tao, L ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :3899-3906
[29]  
WILSON JR, 1990, CARDIOSCIENCE, V1, P13
[30]   OPTICAL SECTIONING IN CONFOCAL FLUORESCENT MICROSCOPES [J].
WILSON, T .
JOURNAL OF MICROSCOPY-OXFORD, 1989, 154 :143-156