Tandem time-of-flight mass spectrometer for phot dissociation of biopolymer ions generated by matrix-assisted laser desorption ionization (MALDI-TOF-PD-TOF) using a linear-plus-quadratic potential reflectron

被引:63
作者
Oh, JY
Moon, JH
Kim, MS [1 ]
机构
[1] Seoul Natl Univ, Natl Creat Res Initiat Ctr Control React Dynam, Seoul 151742, South Korea
[2] Seoul Natl Univ, Sch Chem, Seoul 151742, South Korea
关键词
D O I
10.1016/j.jasms.2004.05.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A tandem time-of-flight mass spectrometer for the study of photodissociation of biopolymer ions generated by matrix-assisted laser desorption ionization was designed and constructed. A reflectron with linear and quadratic (LPQ) potential components was used. Characteristics of the LPQ reflectron and its utility as the second stage analyzer of the tandem mass spectrometer were investigated. Performance of the instrument was tested by observing photodissociation of [M + H](+) from angiotensin 11, a prototype polypeptide. Quality of the photodissociation tandem mass spectrum was almost comparable to that of the post-source decay spectrum. Monoisotopic selection of the parent ion was possible, which was achieved through the ion beam-laser beam synchronization. General theoretical considerations needed for a successful photodissociation of large biopolymer ions are also presented. (C) 2004 American Society for Mass Spectrometry.
引用
收藏
页码:1248 / 1259
页数:12
相关论文
共 40 条
[1]   Sequence and side-chain specific photofragment (193 nm) ions from protonated substance P by matrix-assisted laser desorption ionization time-of-flight mass spectrometry [J].
Barbacci, DC ;
Russell, DH .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (10) :1038-1040
[2]   TANDEM REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER UTILIZING PHOTODISSOCIATION [J].
BEUSSMAN, DJ ;
VLASAK, PR ;
MCLANE, RD ;
SEETERLIN, MA ;
ENKE, CG .
ANALYTICAL CHEMISTRY, 1995, 67 (21) :3952-3957
[3]   Charge/radical site initiation versus coulombic repulsion for cleavage of multiply charged ions. Charge solvation in poly(alkene glycol) ions [J].
Cerda, BA ;
Breuker, K ;
Horn, DM ;
McLafferty, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (05) :565-570
[4]  
Cooks RG, 1973, METASTABLE IONS, P89
[5]   SEQUENCING PEPTIDES WITHOUT SCANNING THE REFLECTRON - POST-SOURCE DECAY WITH A CURVED-FIELD REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER [J].
CORDERO, MM ;
CORNISH, TJ ;
COTTER, RJ ;
LYS, IA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (14) :1356-1361
[6]   TANDEM TIME-OF-FLIGHT MASS-SPECTROMETER [J].
CORNISH, TJ ;
COTTER, RJ .
ANALYTICAL CHEMISTRY, 1993, 65 (08) :1043-1047
[7]   A CURVED FIELD REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER FOR THE SIMULTANEOUS FOCUSING OF METASTABLE PRODUCT IONS [J].
CORNISH, TJ ;
COTTER, RJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (09) :781-785
[8]  
COTTER RJ, 1997, TIME FLIGHT MASS SPE, P47
[9]  
DAL DA, 2000, SIMION 3D VERSION 7
[10]  
Doroshenko VM, 1998, J MASS SPECTROM, V33, P305, DOI 10.1002/(SICI)1096-9888(199804)33:4<305::AID-JMS635>3.0.CO