Handheld rectilinear ion trap mass spectrometer

被引:238
作者
Gao, Liang
Song, Qingyu
Patterson, Garth E.
Cooks, R. Graham [1 ]
Ouyang, Zheng
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[2] Griffin Analyt Technol Inc, W Lafayette, IN 47906 USA
关键词
D O I
10.1021/ac061144k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A shoebox- sized, 10-kg, handheld mass spectrometer, Mini 10, based on a rectilinear ion trap mass analyzer has been designed, built, and characterized. This instrument has evolved from a decade-long experimental and simulation program in mass spectrometer miniaturization. The rectilinear ion trap has a simplified geometry and high trapping capacity, and when used with a miniature and ruggedized pumping system, it allows chemical analysis while the instrument is being carried. Compact electronics, including an air core RF drive coil, were developed to control the instrument and to record mass spectra. The instrument runs on battery power, consuming less than 70 W, similar to a laptop computer. Wired and wireless networking capabilities are implemented. The instrument gives unit resolution and a mass range of over m/z 500. Tandem mass spectrometry capabilities are implemented using collision-induced dissociation, and they are used to provide confirmation of chemical structure during in situ analysis. Continuous monitoring of air and solution samples is demonstrated, and a limit of detection of 50 ppb was obtained for toluene vapor in air and for an aqueous naphthalene solution using membrane sample introduction.
引用
收藏
页码:5994 / 6002
页数:9
相关论文
共 44 条
[11]  
Cotter RJ, 1999, J MASS SPECTROM, V34, P1368, DOI 10.1002/(SICI)1096-9888(199912)34:12<1368::AID-JMS905>3.0.CO
[12]  
2-S
[13]   High-pressure effects in miniature arrays of quadrupole analyzers for residual gas analysis from 10(-9) to 10(-2) Torr [J].
Ferran, RJ ;
Boumsellek, S .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 1996, 14 (03) :1258-1265
[14]  
Franzen J., 1995, PRACTICAL ASPECTS IO, P49
[15]   OPERATION OF A QUADRUPOLE ION TRAP MASS-SPECTROMETER TO ACHIEVE HIGH MASS CHARGE RATIOS [J].
KAISER, RE ;
COOKS, RG ;
STAFFORD, GC ;
SYKA, JEP ;
HEMBERGER, PH .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 106 :79-115
[16]  
KOGAN VT, 1995, INSTRUM EXP TECH+, V38, P106
[17]  
Kornienko O, 1999, RAPID COMMUN MASS SP, V13, P50, DOI 10.1002/(SICI)1097-0231(19990115)13:1<50::AID-RCM449>3.3.CO
[18]  
2-B
[19]  
Lammert SA, 1996, RAPID COMMUN MASS SP, V10, P361, DOI 10.1002/(SICI)1097-0231(199602)10:3<361::AID-RCM477>3.3.CO
[20]  
2-Q