Ultra-Sensitivity Glucose Sensor Based on Field Emitters

被引:17
作者
Liu, Huibiao [1 ]
Qian, Xuemin [1 ,2 ]
Wang, Shu [1 ]
Li, Yuliang [1 ]
Song, Yinglin [2 ]
Zhu, Daoben [1 ]
机构
[1] Chinese Acad Sci, Key Lab Organ Solid, Beijing Natl Lab Mol Sci, Inst Chem, Beijing 100190, Peoples R China
[2] Suzhou Univ, Sch Phys Sci & Technol, Suzhou 215006, Jiangsu, Peoples R China
来源
NANOSCALE RESEARCH LETTERS | 2009年 / 4卷 / 10期
关键词
ZnO nanorod arrays; Glucose sensor; Field emitter; High sensitivity; HYDROGEN-PEROXIDE; OXIDE NANOWIRE; IMMOBILIZATION; BIOSENSORS; BINDING; SURFACE; TIO2;
D O I
10.1007/s11671-009-9372-0
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A new glucose sensor based on field emitter of ZnO nanorod arrays (ZNA) was fabricated. This new type of ZNA field emitter-based sensor shows high sensitivity with experimental limit of detection of 1 nM glucose solution and a detection range from 1 nM to 50 mu M in air at room temperature, which is lower than that of glucose sensors based on surface plasmon resonance spectroscopy, fluorescence signal transmission, and electrochemical signal transduction. The new glucose sensor provides a key technique for promising consuming application in biological system for detecting low levels of glucose on single cells or bacterial cultures.
引用
收藏
页码:1141 / 1145
页数:5
相关论文
共 33 条
[1]   Nanogold plasmon resonance-based glucose sensing. 2. Wavelength-ratiometric resonance light scattering [J].
Aslan, K ;
Lakowicz, JR ;
Geddes, CD .
ANALYTICAL CHEMISTRY, 2005, 77 (07) :2007-2014
[2]   New nanostructured TiO2 for direct electrochemistry and glucose sensor applications [J].
Bao, Shu-Juan ;
Li, Chang Ming ;
Zang, Jian-Feng ;
Cui, Xiao-Qiang ;
Qiao, Yan ;
Guo, Jun .
ADVANCED FUNCTIONAL MATERIALS, 2008, 18 (04) :591-599
[3]   Design, synthesis, and application of particle-based fluorescence resonance energy transfer sensors for carbohydrates and glycoproteins [J].
Blagoi, G ;
Rosenzweig, N ;
Rosenzweig, Z .
ANALYTICAL CHEMISTRY, 2005, 77 (02) :393-399
[4]   The relationship of oxygen binding and peroxide sites and the fluorescent properties of zinc oxide semiconductor nanocrystals [J].
Bohle, D. Scott ;
Spina, Carla J. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2007, 129 (41) :12380-+
[5]   In situ assembled mass-transport controlling micromembranes and their application in implanted amperometric glucose sensors [J].
Chen, T ;
Friedman, KA ;
Lei, I ;
Heller, A .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3757-3763
[6]   Silicon nanowires for high-sensitivity glucose detection [J].
Chen, Weiwei ;
Yao, Hui ;
Tzang, Chi Hung ;
Zhu, Junjie ;
Yang, Mengsu ;
Lee, Shuit-Tong .
APPLIED PHYSICS LETTERS, 2006, 88 (21)
[7]   Selective functionalization of In2O3 nanowire mat devices for biosensing applications [J].
Curreli, M ;
Li, C ;
Sun, YH ;
Lei, B ;
Gundersen, MA ;
Thompson, ME ;
Zhou, CW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (19) :6922-6923
[8]   Use of CdSe/ZnS core-shell quantum dots as energy transfer donors in sensing glucose [J].
Duong, Hong Dinh ;
Il Rhee, Jong .
TALANTA, 2007, 73 (05) :899-905
[9]   Gate-refreshable nanowire chemical sensors [J].
Fan, ZY ;
Lu, JG .
APPLIED PHYSICS LETTERS, 2005, 86 (12) :1-3
[10]   Dual-labeled glucose binding protein for ratiometric measurements of glucose [J].
Ge, XD ;
Tolosa, L ;
Rao, G .
ANALYTICAL CHEMISTRY, 2004, 76 (05) :1403-1410