Underdosage of the upper-airway mucosa for small fields as used in intensity-modulated radiation therapy: A comparison between radiochromic film measurements, Monte Carlo simulations, and collapsed cone convolution calculations

被引:80
作者
Martens, C
Reynaert, N
De Wagter, C
Nilsson, P
Coghe, M
Palmans, H
Theirens, H
De Neve, W
机构
[1] State Univ Ghent Hosp, Div Radiotherapy, B-9000 Ghent, Belgium
[2] State Univ Ghent, Dept Med Phys, B-9000 Ghent, Belgium
[3] Univ Lund Hosp, Dept Radiat Phys, SE-22185 Lund, Sweden
[4] State Univ Ghent, Subatom & Radiat Phys Dept, B-9000 Ghent, Belgium
关键词
air cavity; small fields; radiochromic film; Monte Carlo; collapsed cone convolution calculations;
D O I
10.1118/1.1487421
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Head-and-neck tumors are often situated at an air-tissue interface what may result in an underdosage of part of the tumor in radiotherapy treatments using megavoltage photons. especially for small fields. In addition to effects of transient electronic disequilibrium, for these small fields, an increased lateral electron range in air will result in an important extra reduction of the central axis (lose beyond the cavity. Therefore dose calculation algorithms need to model electron transport accurately. We simulated the trachea by a 2 cm diameter cylindrical air cavity with the rin) situated 2 cm beneath the phantom surface. A 6 MV photon beam from an Elekta SLi plus linear accelerator, equipped with the standard multileaf collimator (MLC), was assessed. A 10 x 2 cm(2) and a 10 K 1 cm(2) field, both widthwise collimated by the MLC, were applied with their long side parallel to the cylinder axis. Central axis dose rebuild-up was studied. Radiochromic film measurements were performed in an in-house manufactured polystyrene phantom with the films oriented either along or perpendicular to the beam axis. Monte Carlo simulations were performed with BEAM and EGSnrc. Calculations were also performed using the pencil beam (PB) algorithm and the collapsed cone convolution (CCC) algorithm of Helax-TMS (MDS Nordion, Kanata. Canada) version 6.0.2 and using the CCC algorithm of Pinnacle (ADAC Laboratories, Milpitas. CA, USA) version 4.2. A very good agreement between the film measurements and the Monte Carlo simulations was found. The CCC algorithms were not able to predict the interface dose accurately when lateral electronic disequilibrium occurs, but were shown to be a considerable improvement compared to the PB algorithm. The CCC algorithms overestimate the dose in the rebuild-up region. The interface dose was overestimated by a maximum of 31% or 54%, depending on the implementation of the CCC algorithm. At a depth of I rum, the maximum dose overestimation was 14% or 24%. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:1528 / 1535
页数:8
相关论文
共 32 条
[1]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[2]   The impact of electron transport on the accuracy of computed dose [J].
Arnfield, MR ;
Siantar, CH ;
Siebers, J ;
Garmon, P ;
Cox, L ;
Mohan, R .
MEDICAL PHYSICS, 2000, 27 (06) :1266-1274
[3]   A COMPARISON OF AIR-CAVITY INHOMOGENEITY EFFECTS FOR CO-60, 6-MV, AND 10-MV X-RAY-BEAMS [J].
BEACH, JL ;
MENDIONDO, MS ;
MENDIONDO, OA .
MEDICAL PHYSICS, 1987, 14 (01) :140-144
[4]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[5]   Extrapolated surface dose measurements with radiochromic film [J].
Butson, MJ ;
Yu, PKN ;
Metcalfe, PE .
MEDICAL PHYSICS, 1999, 26 (03) :485-488
[6]   Linear accelerator based radiosurgery as a salvage treatment for skull base and intracranial invasion of recurrent nasopharyngeal carcinomas [J].
Chen, HJ ;
Leung, SW ;
Su, CY .
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2001, 24 (03) :255-258
[7]   Salvage treatment for persistent and recurrent t1-2 nasopharyngeal carcinoma by stereotactic radiosurgery [J].
Chua, DTT ;
Sham, JST ;
Hung, KN ;
Leung, LHT ;
Cheng, PW ;
Kwong, PWK .
HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2001, 23 (09) :791-798
[8]  
Claus F, 1999, Acta Otorhinolaryngol Belg, V53, P263
[9]   An implementation strategy for IMRT of ethmoid sinus cancer with bilateral sparing of the optic pathways [J].
Claus, F ;
De Gersem, W ;
De Wagter, C ;
Van Severen, R ;
Vanhoutte, I ;
Duthoy, W ;
Remouchamps, V ;
Van Duyse, B ;
Vakaet, L ;
Lemmerling, M ;
Vermeersch, H ;
De Neve, W .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (02) :318-331
[10]   Dose measurements compared with Monte Carlo simulations of narrow 6 MV multileaf collimator shaped photon beams [J].
De Vlamynck, K ;
Palmans, H ;
Verhaegen, F ;
De Wagter, C ;
De Neve, W ;
Thierens, H .
MEDICAL PHYSICS, 1999, 26 (09) :1874-1882