Microcantilever (MCL) biosensing

被引:20
作者
Yan, Xiaodong
Ji, Hai-Feng [1 ]
Thundat, Thomas
机构
[1] Louisiana Tech Univ, Inst Micromfg, Ruston, LA 71272 USA
[2] Oak Ridge Natl Lab, Div Life Sci, Oak Ridge, TN 37830 USA
关键词
D O I
10.2174/157341106777698251
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical community continues to search for cost-effective, reliable, and even portable analytical techniques that can give reliable and fast-response results for a variety of biochemicals. Advances in the field of microelectro-mechanical systems (MEMS) and their uses now offer unique opportunities in the design of ultrasensitive analytical devices. Microcantilevers (MCLs) have been emerged as a novel unique platform for label-free biosensor or bioassay. This short review summarizes the biosensors using microcantilever (MCL) technology. DNA-based, antibody-based, enzyme-based, and membrane-based MCL sensors are discussed. The review is intended to provide an experts in this field an overview of MCL biosensors and to help the non-experts in the field to acquire a good understanding of the development of MCL biosensors and the main issues to be considered for further development of this biosensor technique.
引用
收藏
页码:297 / 307
页数:11
相关论文
共 62 条
  • [11] OBSERVATION OF A CHEMICAL-REACTION USING A MICROMECHANICAL SENSOR
    GIMZEWSKI, JK
    GERBER, C
    MEYER, E
    SCHLITTLER, RR
    [J]. CHEMICAL PHYSICS LETTERS, 1994, 217 (5-6) : 589 - 594
  • [12] Characterisation of an antibody coated microcantilever as a potential immuno-based biosensor
    Grogan, C
    Raiteri, R
    O'Connor, GM
    Glynn, TJ
    Cunningham, V
    Kane, M
    Charlton, M
    Leech, D
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (03) : 201 - 207
  • [13] Investigation of DNA sensing using piezoresistive microcantilever probes
    Gunter, RL
    Zhine, R
    Delinger, WG
    Manygoats, K
    Kooser, A
    Porter, TL
    [J]. IEEE SENSORS JOURNAL, 2004, 4 (04) : 430 - 433
  • [14] Single virus particle mass detection using microresonators with nanoscale thickness
    Gupta, A
    Akin, D
    Bashir, R
    [J]. APPLIED PHYSICS LETTERS, 2004, 84 (11) : 1976 - 1978
  • [15] Nanomechanical forces generated by surface grafted DNA
    Hagan, MF
    Majumdar, A
    Chakraborty, AK
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2002, 106 (39) : 10163 - 10173
  • [16] Cantilever-based optical deflection assay for discrimination of DNA single-nucleotide mismatches
    Hansen, KM
    Ji, HF
    Wu, GH
    Datar, R
    Cote, R
    Majumdar, A
    Thundat, T
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (07) : 1567 - 1571
  • [17] Hybridisation of short DNA molecules investigated with in situ atomic force microscopy
    Holmberg, M
    Kühle, A
    Garnæs, J
    Boisen, A
    [J]. ULTRAMICROSCOPY, 2003, 97 (1-4) : 257 - 261
  • [18] A new residual stress measurement method using ultra-wide micromachined bilayer cantilevers
    Hou, MTK
    Chen, RS
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (04) : 490 - 496
  • [19] Single cell detection with micromechanical oscillators
    Ilic, B
    Czaplewski, D
    Zalalutdinov, M
    Craighead, HG
    Neuzil, P
    Campagnolo, C
    Batt, C
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2001, 19 (06): : 2825 - 2828
  • [20] Mechanical resonant immunospecific biological detector
    Ilic, B
    Czaplewski, D
    Craighead, HG
    Neuzil, P
    Campagnolo, C
    Batt, C
    [J]. APPLIED PHYSICS LETTERS, 2000, 77 (03) : 450 - 452