Background: The effects of beta-radiation with a (188)rhenium (Re-188)-filled balloon catheter system on angiographically normal reference segments have not been well defined. Methods: In the Seoul National University Post-Angioplasty Rhenium irradiation (SPARE) trial, patients with de novo or restenotic lesions were first treated with a conventional catheter-based technique and then randomized to either a radiation group or a control group. Irradiation was performed using a Re-188-filled conventional balloon catheter system. Among 97 radiation group enrolled in this study from April 1998 through May 2001, 20 patients with de novo lesions who received brachytherapy with a balloon at least 10 mm longer than the length of an implanted stent, were selected and their post-intervention and follow-up intravascular ultrasound (IVUS) images were analyzed. Each reference segment was divided into two segments; full dose-irradiation with injury segment (irradiated segment; from the stent edge to the radiopaque balloon markers), and low dose-irradiation without injury segment (edge segment; 5-mm long segment proximal or distal to the location of radiopaque markers). In control group, serial IVUS analysis was available only in 10 patients, and IVUS parameters of the non-stented adjacent segments in these patients were compared to those of irradiated segments in radiation group patients. Results: Forty irradiated and 38 edge segments of the 20 radiation group patients were analyzed. In proximal irradiated segments, no significant changes were found in external elastic membrane (EEM), lumen or in the plaque plus media (P&M) areas. In distal irradiated segments, significant increases in the EEM (12.5 +/- 4.5 to 14.0 +/- 5.0 mm(2), P < 0.01) and P&M areas (5.5 +/- 2.0 to 6.6 +/- 2.3 mm(2), p < 0.01) were found to occur without a change in lumen area. In proximal edge segments, P&M areas were significantly increased (9.0 +/- 1.7 to 10.5 +/- 2.6 mm(2), P = 0.03). No significant changes in EEM, lumen or P&M areas were observed in the distal edge segments. Comparisons between the irradiated segments (n = 40) in the radiation group and the non-stented adjacent segments (n = 19) in the control group showed a significant difference in the percentage change of EEM areas (18.5 +/- 33.2% in radiation group vs. -3.1 +/- 32.1% in control group, P = 0.02). Conclusions: beta-radiation with a Re-188-filled conventional balloon catheter system appears to have no significant deleterious effect on angiographically normal reference segments over a 6 months follow up after brachytherapy. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:73 / 77
页数:5
相关论文
共 14 条
[1]   Safety of intracoronary γ-radiation on uninjured reference segments during the first 6 months after treatment of in-stent restenosis -: A serial intravascular ultrasound study [J].
Ahmed, JM ;
Mintz, GS ;
Waksman, R ;
Weissman, NJ ;
Mehran, R ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Leon, MB .
CIRCULATION, 2000, 101 (19) :2227-2230
[2]   How to fix the edge effect of catheter-based radiation therapy in stented arteries [J].
Cheneau, E ;
Waksman, R ;
Yazdi, H ;
Chan, R ;
Fourdnadjiev, J ;
Berzingi, C ;
Shah, V ;
Ajani, AE ;
Leborgne, L ;
Tio, FO .
CIRCULATION, 2002, 106 (17) :2271-2277
[3]   Intracoronary β-irradiation with a liquid 188Re-filled balloon -: Six-month results from a clinical safety and feasibility study [J].
Höher, M ;
Wöhrle, J ;
Wohlfrom, M ;
Hanke, H ;
Voisard, R ;
Osterhues, HH ;
Kochs, M ;
Reske, SN ;
Hombach, V ;
Kotzerke, J .
CIRCULATION, 2000, 101 (20) :2355-2360
[4]   Impact of geographic miss on adjacent coronary artery segments in diffuse in-stent restenosis with β-radiation therapy:: Angiographic and intravascular ultrasound analysis [J].
Hong, MK ;
Park, SW ;
Moon, DH ;
Oh, SJ ;
Kim, EH ;
Lee, CW ;
Song, JM ;
Kang, DH ;
Song, JK ;
Kim, JJ ;
Park, SJ .
AMERICAN HEART JOURNAL, 2002, 143 (02) :327-333
[5]   Intravascular ultrasound analysis of nonstented adjacent segments in diffuse in-stent restenosis treated with radiation therapy with a rhenium-188-filled balloon [J].
Hong, MK ;
Park, SW ;
Moon, DH ;
Oh, SJ ;
Lee, CW ;
Kim, YH ;
Lee, JW ;
Song, JM ;
Kang, DK ;
Song, JK ;
Kim, JJ ;
Park, SJ .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (04) :428-433
[6]   Dosimetry of rhenium-188 diethylene triamine penta-acetic acid for endovascular intra-balloon brachytherapy after coronary angioplasty [J].
Lee, J ;
Lee, DS ;
Kim, KM ;
Yeo, JS ;
Cheon, GJ ;
Kim, SK ;
Ahn, JY ;
Jeong, JM ;
Chung, JK ;
Lee, MC .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (01) :76-82
[7]   Treatment of diffuse in-scent restenosis with rotational atherectomy followed by radiation therapy with a rhenium-188-mercaptoacetyltriglycine-filled balloon [J].
Park, SW ;
Hong, MK ;
Moon, DH ;
Oh, SJ ;
Lee, CW ;
Kim, JJ ;
Park, SJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (03) :631-637
[8]   Geometric vascular remodeling after balloon angioplasty and β-radiation therapy -: A three-dimensional intravascular ultrasound study [J].
Sabaté, M ;
Serruys, PW ;
van der Giessen, WJ ;
Ligthart, JMR ;
Coen, VLMA ;
Kay, IP ;
Gijzel, AL ;
Wardeh, AJ ;
den Boer, A ;
Levendag, PC .
CIRCULATION, 1999, 100 (11) :1182-1188
[9]   Usefulness of intracoronary brachytherapy for in-stent restenosis with a 188Re liquid-filled balloon [J].
Scühlen, H ;
Eigler, N ;
Whiting, JS ;
Haubner, R ;
Hausleiter, J ;
Dirschinger, J ;
Kastrati, A ;
Schwaiger, M ;
Schömig, A .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (04) :463-+
[10]   Geographical miss during catheter-based intracoronary beta-radiation: Incidence and implications in the BRIE study [J].
Sianos, G ;
Kay, IP ;
Costa, MA ;
Regar, E ;
Kozuma, K ;
de Feyter, PJ ;
Boersma, E ;
Disco, C ;
Serruys, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (02) :415-420