Characteristics and applications of a flat panel computer tomography system

被引:13
作者
Knollmann, F.
Valencia, R.
Buhk, J. -H.
Obenauer, S.
机构
[1] Klinikum Univ Gottingen, Abt Diagnost Radiol, D-37075 Gottingen, Germany
[2] Univ Gottingen, Abt Neuroradiol, D-3400 Gottingen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2006年 / 178卷 / 09期
关键词
experimental study; CT quantitative CT; high resolution CT;
D O I
10.1055/s-2006-926954
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess a new flat panel volume computed tomography (FP-VCT) with very high isotropic spatial resolution as well as high Z-axis coverage. Materials and Methods: The prototype of an FP-VCT scanner with a detector cell size of 0.2 mm was used for numerous phantom studies, specimen examinations, and animal research projects. Results: The high spatial resolution of the new system can be used to accurately determine solid tumor volume, thus allowing for earlier assessment of the therapeutic response. In animal experimentation, whole-body perfusion mapping of mice is feasible. The high spatial resolution also improves the classification of coronary artery atherosclerotic plaques in the isolated post mortem human heart. With the depiction of intramyocardial segments of the coronary arteries, investigations of myocardial collateral circulation are feasible. In skeletal applications, an accurate analysis of the smallest bony structures, e.g., petrous bone and dental preparations, can be successfully performed, as well as investigations of repetitive studies of fracture healing and the treatment of osteoporosis. Conclusion: The introduction of FP-VCT opens up new applications for CT, including the field of molecular imaging, which are highly attractive for future clinical applications. Present limitations include limited temporal resolution and necessitate further improvement of the system.
引用
收藏
页码:862 / 871
页数:10
相关论文
共 35 条
[1]  
Akpek Sergin, 2005, Diagn Interv Radiol, V11, P10
[2]  
Brown P., 2006, P OCEANS 06 AS PAC I, P1
[3]  
Cenic A, 2000, AM J NEURORADIOL, V21, P462
[4]   Stability and instability: Two faces of coronary atherosclerosis - The Paul Dudley White Lecture 1995 [J].
Davies, MJ .
CIRCULATION, 1996, 94 (08) :2013-2020
[5]  
Engelke K, 1999, RADIOLOGE, V39, P203, DOI 10.1007/s001170050497
[6]   Seminars in medicine of the Beth Israel Hospital, Boston - Clinical applications of research on angiogenesis [J].
Folkman, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (26) :1757-1763
[7]  
Gupta R, 2004, AM J NEURORADIOL, V25, P1417
[8]   Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization [J].
Gupta, Rajiv ;
Grasruck, Michael ;
Suess, Christoph ;
Bartling, Soenke H. ;
Schmidt, Bernhard ;
Stierstorfer, Karl ;
Popescu, Stefan ;
Brady, Tom ;
Flohr, Thomas .
EUROPEAN RADIOLOGY, 2006, 16 (06) :1191-1205
[9]   Non-destructive, preclinical evaluation of root canal anatomy of human teeth with flat-panel detector volume CT (FD-VCT) [J].
Heidrich, G ;
Hassepass, F ;
Dullin, C ;
Attin, T ;
Grabbe, E ;
Hannig, C .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (12) :1683-1690
[10]  
Kalender WA, 2003, RADIOLOGE, V43, P379, DOI 10.1007/s00117-003-0897-4