Nitric oxide-releasing sol-gel particle/polyurethane glucose biosensors

被引:59
作者
Shin, JH [1 ]
Marxer, SM [1 ]
Schoenfisch, MH [1 ]
机构
[1] Univ N Carolina, Dept Chem, Chapel Hill, NC 27599 USA
关键词
D O I
10.1021/ac049776z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A hybrid sol-gel/polyurethane glucose biosensor that releases nitric oxide is developed and characterized. The biosensor consists of a platinum electrode coated with four polymeric membranes including the following: (1) sol-gel with immobilized glucose oxidase (GOx); (2) polyurethane to protect the enzyme; (3) NO donormodified sol-gel particle-doped polyurethane; and (4) polyurethane. This configuration was developed due to the drastic reduction in sensitivity observed for NO donormodified sol-gel film-based glucose sensors. For the hybrid sol-gel/polyurethane biosensor, sol-gel particles are first modified with the NO donor and then incorporated into a polyurethane layer that is coated onto the preimmobilized GOx electrode. In this manner, the GOx layer is not exposed to the harsh conditions necessary to impart NO release ability to the biosensor, and only a minimal decrease in sensitivity due to the NO release is observed. The glucose response of the NO-releasing glucose biosensor and its NO generation profiles are reported. In addition, the stability of the sol-gel particles in the supporting polyurethane membrane is discussed.
引用
收藏
页码:4543 / 4549
页数:7
相关论文
共 61 条
[51]  
SHTELZER S, 1994, BIOTECHNOL APPL BIOC, V19, P293
[52]   Nitric oxide-releasing polymers containing the [N(O)NO](-) group [J].
Smith, DJ ;
Chakravarthy, D ;
Pulfer, S ;
Simmons, ML ;
Hrabie, JA ;
Citro, ML ;
Saavedra, JE ;
Davies, KM ;
Hutsell, TC ;
Mooradian, DL ;
Hanson, SR ;
Keefer, LK .
JOURNAL OF MEDICINAL CHEMISTRY, 1996, 39 (05) :1148-1156
[53]   The reactions of copper proteins with nitric oxide [J].
Torres, J ;
Wilson, MT .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 1999, 1411 (2-3) :310-322
[54]   A ferric chloride pre-treatment to prevent calcification of Nafion membrane used for implantable biosensors [J].
Valdes, TI ;
Moussy, F .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (06) :579-585
[55]   Amperometric glucose biosensor based on sol-gel organic-inorganic hybrid material [J].
Wang, BQ ;
Li, B ;
Deng, Q ;
Dong, SJ .
ANALYTICAL CHEMISTRY, 1998, 70 (15) :3170-3174
[56]   Screen-printable sol-gel enzyme-containing carbon inks [J].
Wang, J ;
Pamidi, PVA ;
Park, DS .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2705-2708
[57]   Characterization of implantable biosensor membrane biofouling [J].
Wisniewski, N ;
Moussy, F ;
Reichert, WM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (6-7) :611-621
[58]   ENZYMATIC-ACTIVITY OF GLUCOSE-OXIDASE ENCAPSULATED IN TRANSPARENT GLASS BY THE SOL-GEL METHOD [J].
YAMANAKA, SA ;
NISHIDA, F ;
ELLERBY, LM ;
NISHIDA, CR ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
CHEMISTRY OF MATERIALS, 1992, 4 (03) :495-497
[59]   Elastomers for biomedical applications [J].
Yoda, R .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1998, 9 (06) :561-626
[60]   Nitric oxide releasing silicone rubbers with improved blood compatibility: preparation, characterization, and in vivo evaluation [J].
Zhang, HP ;
Annich, GM ;
Miskulin, J ;
Osterholzer, K ;
Merz, SI ;
Bartlett, RH ;
Meyerhoff, ME .
BIOMATERIALS, 2002, 23 (06) :1485-1494