Imaging articular cartilage defects in the ankle joint with 3D fat-suppressed echo planar imaging: Comparison with conventional 3D fat-suppressed gradient echo imaging

被引:24
作者
Ba-Ssalamah, A [1 ]
Schibany, N [1 ]
Puig, S [1 ]
Herneth, AM [1 ]
Noebauer-Huhmann, IM [1 ]
Trattnig, S [1 ]
机构
[1] Univ Vienna, Dept Radiol, A-1090 Vienna, Austria
关键词
ankle joint; disorder; MRI; 3D FS GRE; 3D FS EPI;
D O I
10.1002/jmri.10153
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To shorten the examination time for articular cartilage imaging, using a recently developed three-dimensional (3D) multishot echo planar imaging (EPI) sequence with fat saturated (FS), compared to aconventional 3D fat-saturated spoiled gradient echo sequence (3D FS GRE). Material and Methods: There were 32 consecutive patients with ankle joint disorders who underwent magnetic resonance imaging (MRI) in a 1.0-T unit. Hyaline cartilage was imaged with a 3D FS EPI sequence and a 3D FS GRE sequence. Image assessment criteria included lesion conspicuity, contrast between different types of normal tissue, and image artifacts. In addition, contrast-to-noise ratios (CNRs) of cartilage vs. joint fluid and bone marrow were measured. Results: The 3D FS EPI sequence provided a high CNR between cartilage and subchondral bone, similar to that of the 3D FS GRE sequence. The CNR between cartilage and effusion was significantly lower on the 3D EPI sequence due to the higher signal intensity of fluid. Both sequences were equal in lesion detection ability. the image quality of the 3D FS GRE sequence was slightly higher than that of the 3D FS EPI, but the difference was not significant. Conclusion: We conclude that the 3D FS EPI sequence is comparable to the 3D FS GRE sequence in the detection of cartilage lesions, with the additional advantage of reduction in scan time by a factor of 4.
引用
收藏
页码:209 / 216
页数:8
相关论文
共 27 条
[1]  
Burstein D, 2001, MAGNET RESON MED, V45, P36, DOI 10.1002/1522-2594(200101)45:1<36::AID-MRM1006>3.0.CO
[2]  
2-W
[3]   INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
THOMPSON, RM ;
JACK, CR .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) :67-72
[4]   ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
FELMLEE, JP ;
GRIMM, RC .
RADIOLOGY, 1993, 189 (01) :259-264
[5]  
CHLANDNANI VP, 1991, RADIOLOGY, V178, P557
[6]   FACTORS INFLUENCING CONTRAST IN FAST SPIN-ECHO MR IMAGING [J].
CONSTABLE, RT ;
ANDERSON, AW ;
ZHONG, J ;
GORE, JC .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :497-511
[7]   DETECTION OF KNEE HYALINE CARTILAGE DEFECTS USING FAT-SUPPRESSED 3-DIMENSIONAL SPOILED GRADIENT-ECHO MR-IMAGING - COMPARISON WITH STANDARD MR-IMAGING AND CORRELATION WITH ARTHROSCOPY [J].
DISLER, DG ;
MCCAULEY, TR ;
WIRTH, CR ;
FUCHS, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :377-382
[8]   FAT-SUPPRESSED SPOILED GRASS IMAGING OF KNEE HYALINE CARTILAGE - TECHNIQUE OPTIMIZATION AND COMPARISON WITH CONVENTIONAL MR-IMAGING [J].
DISLER, DG ;
PETERS, TL ;
MUSCOREIL, SJ ;
RATNER, LM ;
WAGLE, WA ;
COUSINS, JP ;
RIFKIN, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (04) :887-892
[9]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[10]   MR imaging of articular cartilage of the knee: New methods using ultrashort TEs [J].
Gold, GE ;
Thedens, D ;
Pauly, JM ;
Fechner, KP ;
Bergman, G ;
Beaulieu, CF ;
Macovski, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1223-1226