Image plate systems differ in physical performance

被引:28
作者
Borg, E [1 ]
Attaelmanan, A [1 ]
Gröndahl, HG [1 ]
机构
[1] Univ Gothenburg, Dept Oral Diagnost Radiol, Fac Odontol, SE-40530 Gothenburg, Sweden
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS | 2000年 / 89卷 / 01期
关键词
D O I
10.1016/S1079-2104(00)80026-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The purpose of this study was to compare 2 storage phosphor image plate systems, the Digora and the DenOptix, with respect to physical performance. Study design. The 2 systems were tested both with and without use of their default settings through physical and psychophysical measurements. A homogeneous 10-mm-thick aluminum block, a 10-mm-thick aluminum block with a pattern of holes varying in diameter and depth, and a resolving power target were used as rest phantoms. The image plates were exposed at 50 kV and 8 mA with a focus-sensor distance of 30 cm and exposure times ranging from 10 to 3200 ms. Measurements of large area transfer function, gray level variations, perceptibility, contrast resolution, exposure range, and modulation transfer function were performed. Results, When the two systems were used at their default settings, the DenOptix had a better dose response, a higher contrast index, and a higher modulation transfer function (MTF) than the Digora; however, the DenOptix also had higher noise than the Digora at lower exposures. Conclusions. When image enhancement algorithms were applied with the Digora system, performance similar to that of the DenOptix could be obtained.
引用
收藏
页码:118 / 124
页数:7
相关论文
共 28 条
[1]   Assessments of the physical performance of 2 generations of 2 direct digital intraoral sensors [J].
Attaelmanan, AG ;
Borg, E ;
Gröndahl, HG .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1999, 88 (04) :517-523
[2]   EVALUATION OF THE NEW RADIOVISIOGRAPHY SYSTEM IMAGE QUALITY [J].
BENZ, C ;
MOUYEN, F .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1991, 72 (05) :627-631
[3]   On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems [J].
Borg, E ;
Grondahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (02) :82-88
[4]   DETECTOR RESPONSE AND EXPOSURE CONTROL OF THE RADIO VISIOGRAPHY SYSTEM (RVG 32000 ZHR) [J].
CHEN, SK ;
HOLLENDER, L ;
ODONT, D .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1993, 76 (01) :104-111
[5]   PHYSICAL ASPECTS OF PHOTOSTIMULABLE PHOSPHOR COMPUTED RADIOGRAPHY [J].
COWEN, AR ;
WORKMAN, A ;
PRICE, JS .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (784) :332-345
[6]   A PRACTICAL METHOD TO MEASURE THE MTF OF CT SCANNERS [J].
DROEGE, RT ;
MORIN, RL .
MEDICAL PHYSICS, 1982, 9 (05) :758-759
[7]   A PRACTICAL METHOD TO ROUTINELY MONITOR RESOLUTION IN DIGITAL IMAGES [J].
DROEGE, RT .
MEDICAL PHYSICS, 1983, 10 (03) :337-343
[8]  
*GEND DENT SYST, 1997, DEN US MAN INST GUID
[9]   SENS-A-RAY CHARACTERISTICS WITH VARIATIONS IN-BEAM QUALITY [J].
HARADA, T ;
NISHIKAWA, K ;
SHIBUYA, H ;
HAYAKAWA, Y ;
KUROYANAGI, K .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 80 (01) :120-123
[10]   Intraoral radiographic storage phosphor image mean pixel values and signal-to-noise ratio - Effects of calibration [J].
Hayakawa, Y ;
Farman, AG ;
Kelly, MS ;
Kuroyanagi, K .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 86 (05) :601-605