Enhanced detection of Schistosoma circulating antigens by testing 1 ml urine samples using immunomagnetic beads

被引:11
作者
Nibbeling, HAM
VanEtten, L
Fillie, YE
Deelder, AM
机构
[1] Laboratory of Parasitology, University of Leiden, 2300 RC Leiden
关键词
immunomagnetic beads; circulating antigen detection; schistosomiasis; immunodiagnosis;
D O I
10.1016/S0001-706X(97)00039-9
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
The potential advantage of increasing the sample volume for enhanced detection of two Schistosoma circulating antigens in mine has been evaluated, Two different, monoclonal antibody based, immunomagnetic beads assays detecting circulating anodic antigen (CAA) and circulating soluble egg antigen (CSEA), respectively, were investigated. By increasing the sample volume to 1.0 ml, the lower detection limit of antigen dilution series was improved six-eight-fold in both immunomagnetic beads assays. Indeed, an improvement could be shown when testing the urine of Schistosoma-infected individuals with these magnetic beads assays. To compare the sensitivity of the immunomagnetic beads method with the standard ELISA, urine was experimentally adjusted to mirror low natural infection intensities. CSEA-positive urine samples were adjusted to levels below the detection limit of the corresponding ELISA and indeed were still found positive by the CSEA immunomagnetic beads assay. These results demonstrate that by using immunomagnetic beads, an assay method which can utilise larger sample volumes than an ELISA, enhanced detection can be achieved. This might be particularly valuable in areas with low prevalence of schistosomiasis or for the assessment of cure after chemotherapy. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:85 / 92
页数:8
相关论文
共 18 条
[11]  
Hedrum A, 1992, PCR Methods Appl, V2, P167
[12]   CIRCULATING ANODIC AND CATHODIC ANTIGEN IN SERUM AND URINE FROM SCHISTOSOMA-HAEMATOBIUM - INFECTED CAMEROONIAN CHILDREN RECEIVING PRAZIQUANTEL - A LONGITUDINAL-STUDY [J].
KREMSNER, PG ;
ENYONG, P ;
KRIJGER, FW ;
DEJONGE, N ;
ZOTTER, GM ;
THALHAMMER, F ;
MUHLSCHLEGEL, F ;
BIENZLE, U ;
FELDMEIER, H ;
DEELDER, AM .
CLINICAL INFECTIOUS DISEASES, 1994, 18 (03) :408-413
[13]   A RAPID AND SENSITIVE IMMUNOASSAY FOR TUMOR-NECROSIS-FACTOR USING MAGNETIC MONODISPERSE POLYMER PARTICLES [J].
LIABAKK, NB ;
NUSTAD, K ;
ESPEVIK, T .
JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 134 (02) :253-259
[14]   OPTIMIZATION OF THE MAGNETIC BEAD ANTIGEN CAPTURE ENZYME IMMUNE ASSAY FOR THE DETECTION OF CIRCULATING ANODIC ANTIGENS IN MIXED SCHISTOSOMA INFECTIONS [J].
NDHLOVU, P ;
CADMAN, H ;
GUNDERSEN, SG ;
VENNERVALD, B ;
FRIIS, H ;
CHRISTENSEN, N ;
MUTASA, G ;
HAAGENSEN, I ;
CHANDIWANA, SK ;
DEELDER, AM .
ACTA TROPICA, 1995, 59 (03) :223-235
[15]   MAGNETIC SEPARATION TECHNIQUES IN DIAGNOSTIC MICROBIOLOGY [J].
OLSVIK, O ;
POPOVIC, T ;
SKJERVE, E ;
CUDJOE, KS ;
HORNES, E ;
UGELSTAD, J ;
UHLEN, M .
CLINICAL MICROBIOLOGY REVIEWS, 1994, 7 (01) :43-54
[16]  
PAUS E, 1989, CLIN CHEM, V35, P2034
[17]  
RIPERT C, 1988, TROP MED PARASITOL, V39, P131
[18]   IMPROVED DIAGNOSTIC PERFORMANCE OF THE CIRCULATING ANTIGEN-ASSAY IN HUMAN SCHISTOSOMIASIS BY PARALLEL TESTING FOR CIRCULATING ANDODIC AND CATHODIC ANTIGENS IN SERUM AND URINE [J].
VANLIESHOUT, L ;
DEJONGE, N ;
ELMASRY, NA ;
MANSOUR, MM ;
KRIJGER, FW ;
DEELDER, AM .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 1992, 47 (04) :463-469