Temperature study of CdZnTe coplanar-grid detectors

被引:15
作者
Amman, Mark [1 ]
Lee, Julie S. [1 ]
Luke, Paul N. [1 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Berkeley, CA 94720 USA
关键词
CdZnTe; coplanar-grid; gamma-ray detector;
D O I
10.1109/TNS.2006.879909
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The coplanar-grid (CPG) and other electron-only detection techniques have made possible the use of CdZnTe-based detectors for gamma-ray spectroscopy when high efficiency, good energy resolution, and near room temperature operation are required. Despite the demonstrated potential of the technologies, widespread use remains hampered in part by the limited availability of the highly uniform CdZnTe material required for high-resolution spectroscopy. However, it has been recently shown that mild cooling of CdZnTe CPG detectors can result in a significant improvement in the energy resolution of the detectors thereby allowing a wider range of material to be used for high-resolution applications. In this paper, we show that improved spectroscopic performance can consistently be achieved through a combination of detector cooling and increased detector bias. Energy resolutions of about 1% FWHM at 662 keV for detector volumes up to 2.3 cm(3) have been obtained at -20 degrees C. With the electronic noise subtracted, this amounts to an intrinsic resolution of 0.8%. We also show that further cooling of the detectors to -30 degrees C leads to field polarization and a loss of spectroscopic performance.
引用
收藏
页码:3035 / 3040
页数:6
相关论文
共 16 条
[1]   Optimization criteria for coplanar-grid detectors [J].
Amman, M ;
Luke, PN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :205-212
[2]   CdZnTe material uniformity and coplanar-grid gamma-ray detector performance [J].
Amman, M ;
Luke, PN ;
Lee, JS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) :760-767
[3]  
Gostilo V, 2004, IEEE NUCL SCI CONF R, P4590
[4]   Position-sensitive single carrier CdZnTe detectors [J].
He, Z ;
Knoll, GF ;
Wehe, DK ;
Miyamoto, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 388 (1-2) :180-185
[5]   1-D position sensitive single carrier semiconductor [J].
He, Z ;
Knoll, GF ;
Wehe, DK ;
Rojeski, R ;
Mastrangelo, CH ;
Hammig, M ;
Barrett, C ;
Uritani, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :228-231
[6]   UNIPOLAR CHARGE SENSING WITH COPLANAR ELECTRODES - APPLICATION TO SEMICONDUCTOR-DETECTORS [J].
LUKE, PN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :207-213
[7]   Factors affecting energy resolution of coplanar-grid CdZnTe detectors [J].
Luke, PN ;
Amman, M ;
Lee, JS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) :1199-1203
[8]   Pocket-size CdZnTe gamma-ray spectrometer [J].
Luke, PN ;
Amman, M ;
Lee, JS ;
Vu, CQ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) :2041-2044
[9]   SINGLE-POLARITY CHARGE SENSING IN IONIZATION DETECTORS USING COPLANAR ELECTRODES [J].
LUKE, PN .
APPLIED PHYSICS LETTERS, 1994, 65 (22) :2884-2886
[10]   Noise in CdZnTe detectors [J].
Luke, PN ;
Amman, M ;
Lee, JS ;
Manfredi, PF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :282-286