Half-Fourier, three-dimensional technique for dynamic contrast-enhanced MR imaging of both breasts and axillae: Initial characterization of breast lesions

被引:29
作者
Perman, WH [1 ]
Heiberg, EV [1 ]
Herrmann, VM [1 ]
机构
[1] ST LOUIS UNIV,SCH MED,MED CTR,DEPT SURG,ST LOUIS,MO 63110
关键词
breast neoplasms; MR; magnetic resonance (MR); half-Fourier imaging; k-space; technology;
D O I
10.1148/radiology.200.1.8657924
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the ability of asymmetric half-Fourier three-dimensional (3D) magnetic resonance (MR) imaging to characterize signal intensity changes in breasts and axillae after contrast material injection and to compare the spatial resolution and measured signal intensity change of asymmetric and symmetric (keyhole) partial Fourier techniques. MATERIALS AND METHODS: Imaging was performed in 28 adult patients by collecting a single full-Fourier 3D data set with bolus injection of contrast material during the last 10 seconds followed by collection of six half-Fourier 3D data sets without interimage delays. Postcontrast keyhole and half-Fourier images were formed from the same full-Fourier raw data set. RESULTS: The asymmetric half-Fourier 3D technique maintained the spatial resolution and lesion signal intensity of the full-Fourier image, whereas the 50% keyhole method degraded the spatial resolution by a factor of two and decreased the lesion signal intensity by 19% for a 2 x 2-pixel region of interest Histopathologic correlation was attained in 32 lesions in 28 patients. Sensitivity was 100% (five of five) and specificity was 89% (24 of 27). CONCLUSION: The asymmetric half-Fourier 3D MR imaging technique allows imaging of both breasts and axillae without loss of lesion contrast or temporal resolution and provides the maximum spatial resolution and lesion signal intensity attainable for the views sampled.
引用
收藏
页码:263 / 269
页数:7
相关论文
共 40 条
[11]   NONPALPABLE BREAST-TUMORS - DIAGNOSIS WITH CONTRAST-ENHANCED SUBTRACTION DYNAMIC MR-IMAGING [J].
GILLES, R ;
GUINEBRETIERE, JM ;
LUCIDARME, O ;
CLUZEL, P ;
JANAUD, G ;
FINET, JF ;
TARDIVON, A ;
MASSELOT, J ;
VANEL, D .
RADIOLOGY, 1994, 191 (03) :625-631
[12]  
GREENSTEIN O, 1995, RADIOLOGY, V196, P115
[13]   IMPROVED CONTRAST AT 1.5 TESLA USING HALF-FOURIER IMAGING - APPLICATION TO SPIN-ECHO AND ANGIOGRAPHIC IMAGING [J].
HAACKE, EM ;
MITCHELL, J ;
LEE, DH .
MAGNETIC RESONANCE IMAGING, 1990, 8 (01) :79-90
[14]   CONSTRAINED RECONSTRUCTION - A SUPERRESOLUTION, OPTIMAL SIGNAL-TO-NOISE ALTERNATIVE TO THE FOURIER-TRANSFORM IN MAGNETIC-RESONANCE IMAGING [J].
HAACKE, EM ;
LIANG, ZP ;
IZEN, SH .
MEDICAL PHYSICS, 1989, 16 (03) :388-397
[15]  
Hachiya J, 1991, Radiat Med, V9, P232
[16]   MR-IMAGING OF THE BREAST WITH ROTATING DELIVERY OF EXCITATION OFF RESONANCE - CLINICAL-EXPERIENCE WITH PATHOLOGICAL CORRELATION [J].
HARMS, SE ;
FLAMIG, DP ;
HESLEY, KL ;
MEICHES, MD ;
JENSEN, RA ;
EVANS, WP ;
SAVINO, DA ;
WELLS, RV .
RADIOLOGY, 1993, 187 (02) :493-501
[17]   Dynamic sequential 3D gadolinium-enhanced MRI of the whole breast [J].
Heiberg, EV ;
Perman, WH ;
Herrmann, VM ;
Janney, CG .
MAGNETIC RESONANCE IMAGING, 1996, 14 (04) :337-348
[18]   GD-DTPA ENHANCED MR IMAGING OF THE BREAST IN PATIENTS WITH POSTOPERATIVE SCARRING AND SILICON IMPLANTS [J].
HEYWANG, SH ;
HILBERTZ, T ;
BECK, R ;
BAUER, WM ;
EIERMANN, W ;
PERMANETTER, W .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) :348-356
[19]  
Heywang-Koebrunner SH, 1993, ELEKTROMEDICA, V61, P43
[20]   CONTRAST-ENHANCED MR-IMAGING OF THE BREAST - COMPARISON OF 2 DIFFERENT DOSES OF GADOPENTETATE DIMEGLUMINE [J].
HEYWANGKOBRUNNER, SH ;
HAUSTEIN, J ;
POHL, C ;
BECK, R ;
LOMMATZSCH, B ;
UNTCH, M ;
NATHRATH, WBJ .
RADIOLOGY, 1994, 191 (03) :639-646