Clinically Significant Gains in Skillful Grasp Coordination by an Individual With Tetraplegia Using an Implanted Brain-Computer Interface With Forearm Transcutaneous Muscle Stimulation

被引:41
作者
Bockbrader, Marcie [1 ,2 ,3 ]
Annetta, Nicholas [4 ]
Friedenberg, David [4 ]
Schwemmer, Michael [4 ]
Skomrock, Nicholas [4 ]
Colachis, Samuel [1 ,3 ,4 ]
Zhang, Mingming [4 ]
Bouton, Chad [4 ,5 ]
Rezai, Ali [2 ,6 ]
Sharma, Gaurav [4 ]
Mysiw, Walter J. [1 ,2 ]
机构
[1] Ohio State Univ, Dept Phys Med & Rehabil, 480 Med Ctr Dr, Columbus, OH 43210 USA
[2] Ohio State Univ, Wexner Med Ctr, Neurol Inst, Columbus, OH 43210 USA
[3] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[4] Battelle Mem Inst, 505 King Ave, Columbus, OH 43201 USA
[5] Feinstein Inst Med Res, Ctr Bioelect Med, Manhasset, NY USA
[6] West Virginia Univ, Rockefeller Neurosci Inst, Morgantown, WV 26506 USA
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2019年 / 100卷 / 07期
关键词
Activities of daily living; Brain-computer interfaces; Hand strength; Quadriplegia; Rehabilitation; Transcutaneous electric nerve stimulation; FUNCTIONAL ELECTRICAL-STIMULATION; SPINAL-CORD-INJURY; GRADED REDEFINED ASSESSMENT; UPPER-LIMB; HAND GRASP; NEUROMUSCULAR STIMULATION; FUNCTION-TESTS; RELEASE TEST; NEUROPROSTHESIS; RELIABILITY;
D O I
10.1016/j.apmr.2018.07.445
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To demonstrate naturalistic motor control speed, coordinated grasp, and carryover from trained to novel objects by an individual with tetraplegia using a brain-computer interface (BCI)-controlled neuroprosthetic. Design: Phase I trial for an intracortical BCI integrated with forearm functional electrical stimulation (FES). Data reported span postimplant days 137 to 1478. Setting: Tertiary care outpatient rehabilitation center. Participant: A 27-year-old man with C5 class A (on the American Spinal Injury Association Impairment Scale) traumatic spinal cord injury Interventions: After array implantation in his left (dominant) motor cortex, the participant trained with BCI-FES to control dynamic, coordinated forearm, wrist, and hand movements. Main Outcome Measures: Performance on standardized tests of arm motor ability (Graded Redefined Assessment of Strength, Sensibility, and Prehension [GRASSP], Action Research Arm Test [ARAT], Grasp and Release Test [GRT], Box and Block Test), grip myometry, and functional activity measures (Capabilities of Upper Extremity Test [CUE-T], Quadriplegia Index of Function-Short Form [QIF-SF], Spinal Cord Independence Measure-Self-Report [SCIM-SR]) with and without the BCI-FES. Results: With BCI-FES, scores improved from baseline on the following: Grip force (2.9 kg); ARAT cup, cylinders, ball, bar, and blocks; GRT can, fork, peg, weight, and tape; GRASSP strength and prehension (unscrewing lids, pouring from a bottle, transferring pegs); and CUE-T wrist and hand skills. QIF-SF and SCIM-SR eating, grooming, and toileting activities were expected to improve with home use of BCI-FES. Pincer grips and mobility were unaffected. BCI-FES grip skills enabled the participant to play an adapted "Battleship" game and manipulate household objects. Conclusions: Using BCI-FES, the participant performed skillful and coordinated grasps and made clinically significant gains in tests of upper limb function. Practice generalized from training objects to household items and leisure activities. Motor ability improved for palmar, lateral, and tip-to-tip grips. The expects eventual home use to confer greater independence for activities of daily living, consistent with observed neurologic level gains from C5-6 to C7-T1. This marks a critical translational step toward clinical viability for BCI neuroprosthetics. (C) 2021 The Authors. Published by Elsevier Inc. on behalf of The American Congress of Rehabilitation Medicine. This is an open access article under the CC BY-NC-ND licensc (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1201 / 1217
页数:17
相关论文
共 67 条
  • [11] Validation of the NIH Toolbox in Individuals with Neurologic Disorders
    Carlozzi, N. E.
    Goodnight, S.
    Casaletto, K. B.
    Goldsmith, A.
    Heaton, R. K.
    Wong, A. W. K.
    Baum, C. M.
    Gershon, R.
    Heinemann, A. W.
    Tulsky, D. S.
    [J]. ARCHIVES OF CLINICAL NEUROPSYCHOLOGY, 2017, 32 (05) : 555 - 573
  • [12] Test-Retest Reproducibility and Smallest Real Difference of 5 Hand Function Tests in Patients With Stroke
    Chen, Hui-Mei
    Chen, Christine C.
    Hsueh, I-Ping
    Huang, Sheau-Ling
    Hsieh, Ching-Lin
    [J]. NEUROREHABILITATION AND NEURAL REPAIR, 2009, 23 (05) : 435 - 440
  • [13] Dexterous Control of Seven Functional Hand Movements Using Cortically-Controlled Transcutaneous Muscle Stimulation in a Person With Tetraplegia
    Colachis, Samuel C.
    Bockbrader, Marcie A.
    Zhang, Mingming
    Friedenberg, David A.
    Annetta, Nicholas V.
    Schwemmer, Michael A.
    Skomrock, Nicholas D.
    Mysiw, Walter J.
    Rezai, Ali R.
    Bresler, Herbert S.
    Sharma, Gaurav
    [J]. FRONTIERS IN NEUROSCIENCE, 2018, 12
  • [14] Colachis SC, 2018, THESIS, P42
  • [15] High-performance neuroprosthetic control by an individual with tetraplegia
    Collinger, Jennifer L.
    Wodlinger, Brian
    Downey, John E.
    Wang, Wei
    Tyler-Kabara, Elizabeth C.
    Weber, Douglas J.
    McMorland, Angus J. C.
    Velliste, Meel
    Boninger, Michael L.
    Schwartz, Andrew B.
    [J]. LANCET, 2013, 381 (9866) : 557 - 564
  • [16] Functional priorities, assistive technology, and brain-computer interfaces after spinal cord injury
    Collinger, Jennifer L.
    Boninger, Michael L.
    Bruns, Tim M.
    Curley, Kenneth
    Wang, Wei
    Weber, Douglas J.
    [J]. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2013, 50 (02) : 145 - 159
  • [17] Clinical Reality of Measuring Upper-Limb Ability in Neurologic Conditions: A Systematic Review
    Connell, Louise A.
    Tyson, Sarah F.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (02): : 221 - 228
  • [18] Motor cortical activity changes during neuroprosthetic-controlled object interaction
    Downey, John E.
    Brane, Lucas
    Gaunt, Robert A.
    Tyler-Kabara, Elizabeth C.
    Boninger, Michael L.
    Collinger, Jennifer L.
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [19] Intracortical microstimulation of human somatosensory cortex
    Flesher, Sharlene N.
    Collinger, Jennifer L.
    Foldes, Stephen T.
    Weiss, Jeffrey M.
    Downey, John E.
    Tyler-Kabara, Elizabeth C.
    Bensmaia, Sliman J.
    Schwartz, Andrew B.
    Boninger, Michael L.
    Gaunt, Robert A.
    [J]. SCIENCE TRANSLATIONAL MEDICINE, 2016, 8 (361)
  • [20] Neuroprosthetic-enabled control of graded arm muscle contraction in a paralyzed human
    Friedenberg, David A.
    Schwemmer, Michael A.
    Landgraf, Andrew J.
    Annetta, Nicholas V.
    Bockbrader, Marcia A.
    Bouton, Chad E.
    Zhang, Mingming
    Rezai, Ali R.
    Mysiw, W. Jerry
    Bresler, Herbert S.
    Sharma, Gaurav
    [J]. SCIENTIFIC REPORTS, 2017, 7