A disposable amperometric sensor screen printed on a nitrocellulose strip: A glucose biosensor employing lead oxide as an interference-removing agent

被引:80
作者
Cui, G
Kim, SJ
Choi, SH
Nam, H
Cha, GS
Paeng, KJ
机构
[1] Kwangwoon Univ, Dept Chem, Chem Sensor Res Grp, Seoul 139701, South Korea
[2] Yonsei Univ, Dept Chem, Wonju 220710, South Korea
关键词
D O I
10.1021/ac991213d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new type of disposable amperometric sensor is devised by screen printing thick-film electrodes directly on a porous nitrocellulose (NC) strip. The chromatographic NC strip is then utilized to introduce various sample pretreatment layers. As a preliminary application, a glucose biosensor based on hydrogen peroxide detection is constructed by immobilizing glucose oxidase (GOx) on the NC electrode strip and by formulating a strong oxidation layer (i.e., PbO2) at the sample loading area, placed below the GOx reaction band. The screen-printed PbO2 paste serves as a sample pretreatment layer that removes interference by its strong oxidizing ability. Samples applied are carried chromatographically, via the PbO2 paste, to the GOx layer, and glucose is catalyzed to liberate hydrogen peroxide, which is then detected at the electrode surface. The proposed NC/PbO2 strip sensor is shown to be virtually insusceptible to interfering species such as acetaminophen and ascorbic and uric acids and to exhibit good performance, in terms of the sensor-to-sensor reproducibility (standard deviation, +/-0.026-+/-0.086 mu A), the sensitivity (slope, -0.183 mu A/mM), and the linearity (correlation coefficient, 0.994 in the range of 0-10 mM).
引用
收藏
页码:1925 / 1929
页数:5
相关论文
共 24 条
  • [1] Subfemtomolar determination of alkaline phosphatase at a disposable screen-printed electrode modified with a perfluorosulfonated ionomer film
    Bagel, O
    Limoges, B
    Schollhorn, B
    Degrand, C
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (22) : 4688 - 4694
  • [2] Development of a new immunosensor for pesticide detection: a disposable system with liposome-enhancement and amperometric detection
    Baumner, AJ
    Schmid, RD
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (05) : 519 - 529
  • [3] BRADSHAW P, 1995, CLIN CHEM, V41, P1360
  • [4] FABRICATION AND CHARACTERIZATION OF A SCREEN-PRINTED, DISPOSABLE, AMPEROMETRIC CHOLESTEROL BIOSENSOR
    GILMARTIN, MAT
    HART, JP
    [J]. ANALYST, 1994, 119 (11) : 2331 - 2336
  • [5] SENSING WITH CHEMICALLY AND BIOLOGICALLY MODIFIED CARBON ELECTRODES
    GILMARTIN, MAT
    HART, JP
    [J]. ANALYST, 1995, 120 (04) : 1029 - 1045
  • [6] VOLTAMMETRIC AND AMPEROMETRIC BEHAVIOR OF URIC-ACID AT BARE AND SURFACE-MODIFIED SCREEN-PRINTED ELECTRODES - STUDIES TOWARDS A DISPOSABLE URIC-ACID SENSOR
    GILMARTIN, MAT
    HART, JP
    [J]. ANALYST, 1992, 117 (08) : 1299 - 1303
  • [7] Studies towards a disposable screen-printed amperometric biosensor for progesterone
    Hart, JP
    Pemberton, RM
    Luxton, R
    Wedge, R
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (11) : 1113 - 1121
  • [8] Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses
    Hart, JP
    Wring, SA
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (02) : 89 - 103
  • [9] A DISPOSABLE AMPEROMETRIC IMMUNOSENSOR FOR 2,4-DICHLOROPHENOXYACETIC ACID
    KALAB, T
    SKLADAL, P
    [J]. ANALYTICA CHIMICA ACTA, 1995, 304 (03) : 361 - 368
  • [10] Disposable creatinine sensor based on thick-film hydrogen peroxide electrode system
    Kim, EJ
    Haruyama, T
    Yanagida, Y
    Kobatake, E
    Aizawa, M
    [J]. ANALYTICA CHIMICA ACTA, 1999, 394 (2-3) : 225 - 231