Superficial doses from serial tomotherapy delivery

被引:34
作者
Mutic, S [1 ]
Low, DA [1 ]
机构
[1] Washington Univ, Sch Med, Edward Mallinckrodt Inst Radiol, Radiat Oncol Ctr, St Louis, MO 63110 USA
关键词
intensity modulated radiation therapy; serial tomotherapy; dose measurements;
D O I
10.1118/1.598880
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Serial tomotherapy patients are treated using a commercial computer-controlled treatment planning and delivery system and a linear accelerator in are mode. Target volumes are irradiated using sequential 1.68-cm-thick slices with the patient moved between each successive slice delivery. Due to the method of delivery, superficial doses from a course of intensity modulated radiation therapy may be significantly different from doses delivered with conventional radiation therapy. An experimental investigation was conducted to determine the superficial depth-dose distribution for geometric target volumes. Treatment plans were conducted for 5-cm-diam, 5-cm-long right cylindrical target volumes embedded in a 16-cm-diam, 12-cm-long water-equivalent cylindrical phantom. Three experiments were conducted with centrally located, off-centered, and superficial targets. Doses at superficial depths were measured using 3 X 3 X 1 mm(3) thermoluminescent dosimetry chips. For all three targets, the measured doses were slightly greater than the calculated doses. Doses measured in the buildup region for the superficial target indicated that bolus would be required to provide the prescribed dose at the phantom surface. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00301-1].
引用
收藏
页码:163 / 165
页数:3
相关论文
共 9 条
[1]  
CAROL MP, 1993, 3D RAD TREATMENT PLA
[2]   Estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapy [J].
Followill, D ;
Geis, P ;
Boyer, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (03) :667-672
[3]  
Followill DS, 1997, INT J RADIAT ONCOL, V39, P783
[4]  
GRANT W, 1996, P 1996 AAPM SUMM SCH
[5]   Commercial IMRT treatment-planning dose-calculation algorithm [J].
Low, DA ;
Mutic, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04) :933-937
[6]   Quantitative dosimetric verification of an IMRT planning and delivery system [J].
Low, DA ;
Mutic, S ;
Dempsey, JF ;
Gerber, RL ;
Bosch, WR ;
Perez, CA ;
Purdy, JA .
RADIOTHERAPY AND ONCOLOGY, 1998, 49 (03) :305-316
[7]   Abutment region dosimetry for sequential arc IMRT delivery [J].
Low, DA ;
Mutic, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (07) :1465-1470
[8]   Whole-body dose from tomotherapy delivery [J].
Mutic, S ;
Low, DA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (01) :229-232
[9]   Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck region [J].
Verellen, D ;
Linthout, N ;
VandenBerge, D ;
Bel, A ;
Storme, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01) :99-114