Cystatin C-based calculation of glomerular filtration rate in kidney transplant recipients

被引:77
作者
Poege, U.
Gerhardt, T.
Stoffel-Wagner, B.
Palmedo, H.
Klehr, H. U.
Sauerbruch, T.
Woitas, R. P.
机构
[1] Univ Bonn, Dept Internal Med 1, D-53105 Bonn, Germany
[2] Univ Bonn, Dept Clin Biochem, D-5300 Bonn, Germany
[3] Univ Bonn, Dept Nucl Med, D-5300 Bonn, Germany
关键词
cystatin C equation; glomerular filtration rate; renal transplantation; MDRD;
D O I
10.1038/sj.ki.5001502
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Cystatin C (Cys C) has been shown to be an alternative marker of renal function. However, estimation of the glomerular filtration rate (GFR) based on Cys C has received little attention. Recently, several Cys C-based equations were developed in different patient cohorts. To date, the benefit of a Cys C-based GFR calculation in patients after renal transplantation (RTx) remains to be elucidated. We compared the diagnostic accuracy of three Cys C-based formulae (Larsson, Hoek, Filler which used an immunonephelometric method) with the results of the Modification of Diet in Renal Disease (MDRD) formula. GFR was measured by means of technetium-diethylenetriamine pentaacetic acid (Tc-99m-DTPA) clearance in 108 consecutive patients after RTx. Correlation coefficients of all calculated GFR estimates with the true GFR were high but did not differ significantly from one another (0.83-0.87). The MDRD and Filler equations overestimated GFR significantly, whereas the Larsson equation significantly underestimated GFR. Bias of the Hoek formula was negligible. Precision of the Hoek (8.9 ml/min/ 1.73 m(2)) and Larsson equations (9.6 ml/min/1.73 m(2)) were significantly better than MDRD equations (11.4 ml/min/ 1.73 m(2); P <= 0.035 each). Accuracy within 30% of real GFR was 67.0 and 65.1% for the MDRD and Filler formulae, and 77.1% for the Larsson and Hoek formulae, respectively. Accuracy within 50% of true GFR for the Hoek formula (97.2%) was better than for the MDRD equations (85.3%). Cys C-based formulae may provide a better diagnostic performance than creatinine-based equations in GFR calculation after RTx.
引用
收藏
页码:204 / 210
页数:7
相关论文
共 29 条
[11]   Validation of the modification of diet in renal disease formula for estimating GFR with special emphasis on calibration of the serum creatinine assay [J].
Hallan, S ;
Åsberg, A ;
Lindberg, M ;
Johnsen, H .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2004, 44 (01) :84-93
[12]   Cystatin C - an accurate marker of glomerular filtration rate after renal transplantation? [J].
Herget-Rosenthal, S ;
Trabold, S ;
Huesing, J ;
Heemann, U ;
Philipp, T ;
Kribben, A .
TRANSPLANT INTERNATIONAL, 2000, 13 (04) :285-289
[13]   A comparison between cystatin C, plasma creatinine and the Cockcroft and Gault formula for the estimation of glomerular filtration rate [J].
Hoek, FJ ;
Kemperman, FAW ;
Krediet, RT .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2003, 18 (10) :2024-2031
[14]  
Kasiske BL, 2000, J AM SOC NEPHROL, V11, pS1
[15]   Formula-derived prediction of the glomerular filtration rate from plasma creatinine concentration [J].
Kemperman, FAW ;
Krediet, RT ;
Arisz, L .
NEPHRON, 2002, 91 (04) :547-558
[16]   CREATININE ASSAY BY A REACTION-KINETIC PRINCIPLE [J].
LARSEN, K .
CLINICA CHIMICA ACTA, 1972, 41 (01) :209-&
[17]   Calculation of glomerular filtration rate expressed in mL/min from plasma cystatin C values in mg/L [J].
Larsson, A ;
Malm, J ;
Grubb, A ;
Hansson, LO .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2004, 64 (01) :25-30
[18]  
Laterza OF, 2002, CLIN CHEM, V48, P699
[19]   Comparison of cross-sectional renal function measurements in African Americans with hypertensive nephrosclerosis and of primary formulas to estimate glomerular filtration rate [J].
Lewis, J ;
Agodoa, L ;
Cheek, D ;
Greene, T ;
Middleton, J ;
O'Connor, D ;
Ojo, A ;
Phillips, R ;
Sika, M ;
Wright, J .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2001, 38 (04) :744-753
[20]   Assessing renal graft function in clinical trials: Can tests predicting glomerular filtration rate substitute for a reference method? [J].
Mariat, C ;
Alamartine, E ;
Barthelemy, JC ;
De Filippis, JP ;
Thibaudin, D ;
Berthoux, P ;
Laurent, B ;
Thibaudin, L ;
Berthoux, F .
KIDNEY INTERNATIONAL, 2004, 65 (01) :289-297