Submicrometer axial resolution optical coherence tomography

被引:396
作者
Povazay, B
Bizheva, K
Unterhuber, A
Hermann, B
Sattmann, H
Fercher, AF
Drexler, W
Apolonski, A
Wadsworth, WJ
Knight, JC
Russell, PSJ
Vetterlein, M
Scherzer, E
机构
[1] Univ Vienna, Christian Doppler Lab, Inst Med Phys, A-1090 Vienna, Austria
[2] Vienna Univ Technol, Christian Doppler Lab, Photon Inst, Vienna, Austria
[3] Univ Bath, Dept Phys, Optoelect Grp, Bath, Avon, England
[4] Univ Vienna, Inst Histol & Embryol, A-1090 Vienna, Austria
关键词
D O I
10.1364/OL.27.001800
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography (OCT) with unprecedented submicrometer axial resolution achieved by use of a photonic crystal fiber in combination with a compact sub-10-fs Ti:sapphire laser (Femtolasers Produktions) is demonstrated for what the authors believe is the first time. The emission spectrum ranges from 550 to 950 nm (lambda(c) = 725 nm, P-out = 27 mW), resulting in a free-space axial OCT resolution of similar to0.75 mum, corresponding to similar to0.5 mum in biological tissue. Submicrometer-resolution OCT is demonstrated in vitro on human colorectal adenocarcinoma cells HT-29. This novel light source has great potential for development of spectroscopic OCT because its spectrum covers the absorption bands of several biological chromophores. (C) 2002 Optical Society of America.
引用
收藏
页码:1800 / 1802
页数:3
相关论文
共 13 条
  • [1] Spectral shaping of supercontinuum in a cobweb photonic-crystal fiber with sub-20-fs pulses
    Apolonski, A
    Povazay, B
    Unterhuber, A
    Drexler, W
    Wadsworth, WJ
    Knight, JC
    Russell, PS
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2002, 19 (09) : 2165 - 2170
  • [2] Supercontinuum generation in tapered fibers
    Birks, TA
    Wadsworth, WJ
    Russell, PS
    [J]. OPTICS LETTERS, 2000, 25 (19) : 1415 - 1417
  • [3] OPTICAL LOW COHERENCE REFLECTOMETRY WITH 1-BULLET-9 MU-M SPATIAL-RESOLUTION
    CLIVAZ, X
    MARQUISWEIBLE, F
    SALATHE, RP
    [J]. ELECTRONICS LETTERS, 1992, 28 (16) : 1553 - 1555
  • [4] In vivo ultrahigh-resolution optical coherence tomography
    Drexler, W
    Morgner, U
    Kärtner, FX
    Pitris, C
    Boppart, SA
    Li, XD
    Ippen, EP
    Fujimoto, JG
    [J]. OPTICS LETTERS, 1999, 24 (17) : 1221 - 1223
  • [5] Ultrahigh-resolution ophthalmic optical coherence tomography
    Drexler, W
    Morgner, U
    Ghanta, RK
    Kärtner, FX
    Schuman, JS
    Fujimoto, JG
    [J]. NATURE MEDICINE, 2001, 7 (04) : 502 - 507
  • [6] Fercher A F, 1996, J Biomed Opt, V1, P157, DOI 10.1117/12.231361
  • [7] A thermal light source technique for optical coherence tomography
    Fercher, AF
    Hitzenberger, CK
    Sticker, M
    Moreno-Barriuso, E
    Leitgeb, R
    Drexler, W
    Sattmann, H
    [J]. OPTICS COMMUNICATIONS, 2000, 185 (1-3) : 57 - 64
  • [8] OPTICAL BIOPSY AND IMAGING USING OPTICAL COHERENCE TOMOGRAPHY
    FUJIMOTO, JG
    BREZINSKI, ME
    TEARNEY, GJ
    BOPPART, SA
    BOUMA, B
    HEE, MR
    SOUTHERN, JF
    SWANSON, EA
    [J]. NATURE MEDICINE, 1995, 1 (09) : 970 - 972
  • [9] Ultrahigh-resolution optical coherence tomography using continuum generation in an air-silica microstructure optical fiber
    Hartl, I
    Li, XD
    Chudoba, C
    Ghanta, RK
    Ko, TH
    Fujimoto, JG
    Ranka, JK
    Windeler, RS
    [J]. OPTICS LETTERS, 2001, 26 (09) : 608 - 610
  • [10] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181