Simultaneous determination of diazepam and pyridoxine in synthetic mixtures and pharmaceutical formulations using graphical and multivariate calibration-prediction methods

被引:30
作者
Bautista, RD [1 ]
Jiminez, AI [1 ]
Jimenez, F [1 ]
Arias, JJ [1 ]
机构
[1] UNIV LA LAGUNA, FAC QUIM, DEPT QUIM ANALIT NUTR & BROMATOL, E-38071 San Cristobal la Laguna, TENERIFE, SPAIN
关键词
derivative quotient spectra; diazepam; multiple linear regression; partial least-squares regression; pharmaceutical preparations; pyridoxine; zero-crossing;
D O I
10.1016/0731-7085(96)01844-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several methods are reported for the simultaneous determination of diazepam and pyridoxine: two graphical methods (zero-crossing and derivative quotient spectra); and two numerical methods (multiple linear regression and partial least-squares regression). The methods have been applied in the concentration ranges 1.4-4.0 mu g ml(-1) diazepam and 4.0-12.0 mu g ml(-1) pyridoxine. The accuracy and precision of the methods have been determined and they have been validated by analysing synthetic mixtures containing the two drugs in variable proportions. The methods were also applied to the determination of diazepam and pyridoxine in pharmaceutical preparations. The analytical results were quite good in all cases.
引用
收藏
页码:183 / 192
页数:10
相关论文
共 29 条
[1]  
ANTALICK JP, 1988, ANALUSIS, V16, pR13
[2]   MULTICOMPONENT ANALYSIS - COMPARISON OF VARIOUS GRAPHICAL AND NUMERICAL-METHODS [J].
BAUTISTA, RD ;
JIMENEZ, F ;
JIMENEZ, AI ;
ARIAS, JJ .
TALANTA, 1993, 40 (11) :1687-1694
[3]   SPECTROPHOTOMETRIC DETERMINATION OF PHARMACEUTICAL DOSAGES BY PARTIAL LEAST-SQUARES CALIBRATION [J].
BLANCO, M ;
COELLO, J ;
GONZALEZ, F ;
ITURRIAGA, H ;
MASPOCH, S ;
TOMAS, X .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (04) :509-514
[4]   SIMULTANEOUS DETERMINATION OF METAL-IONS - SPECTROPHOTOMETRIC DETERMINATION OF BINARY, TERNARY AND QUATERNARY MIXTURES OF ALUMINUM, IRON, COPPER, TITANIUM AND NICKEL BY EXTRACTION WITH 8-HYDROXYQUINOLINE [J].
BLANCO, M ;
COELLO, J ;
GONZALEZ, F ;
ITURRIAGA, H ;
MASPOCH, S .
ANALYTICA CHIMICA ACTA, 1989, 226 (02) :271-279
[5]   DIODE-ARRAY DETECTORS IN FLOW-INJECTION ANALYSIS - MIXTURE RESOLUTION BY MULTI-WAVELENGTH ANALYSIS [J].
BLANCO, M ;
GENE, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J .
TALANTA, 1987, 34 (12) :987-993
[6]   SIMULTANEOUS DETERMINATION OF ACETAMINOPHEN AND CAFFEINE IN TABLET PREPARATIONS BY PARTIAL LEAST-SQUARES MULTIVARIATE SPECTROPHOTOMETRIC CALIBRATION [J].
BOZDOGAN, A ;
ACAR, AM ;
KUNT, GK .
TALANTA, 1992, 39 (08) :977-979
[7]  
BUN H, 1989, ANAL LETT, V22, P897
[8]   MULTICOMPONENT ANALYSIS OF ENVIRONMENTAL MATRICES [J].
CERDA, V ;
ESTELA, JM ;
FORTEZA, R ;
CLADERA, A ;
GOMEZ, E ;
OMS, MT .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1993, 52 (1-4) :159-178
[9]  
*COMP AID MODE AS, 1993, UNSCR V 5 0
[10]   SIMULTANEOUS DETERMINATION OF METHAQUALONE AND DIAZEPAM IN PLASMA BY DERIVATIVE SPECTROSCOPY [J].
CRUZ, A ;
BERMEJO, A ;
LOPEZRIVADULLA, M ;
FERNANDEZ, P .
ANALYTICAL LETTERS, 1992, 25 (02) :253-268