Imaging cells and extracellular matrix in vivo by using second-harmonic generation and two-photon excited fluorescence

被引:753
作者
Zoumi, A
Yeh, A
Tromberg, BJ [1 ]
机构
[1] Univ Calif Irvine, Laser Microbeam & Med Program, LAMMP, Beckman Laser Inst, Irvine, CA 92612 USA
[2] Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA
关键词
D O I
10.1073/pnas.172368799
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Multiphoton microscopy relies on nonlinear light-matter interactions to provide contrast and optical sectioning capability for high-resolution imaging. Most multiphoton microscopy studies in biological systems have relied on two-photon excited fluorescence (TPEF) to produce images. With increasing applications of multiphoton microscopy to thick-tissue "intravital" imaging, second-harmonic generation (SHG) from structural proteins has emerged as a potentially important new contrast mechanism. However, SHG is typically detected in transmission mode, thus limiting TPEF/SHG coregistration and its practical utility for in vivo thick-tissue applications. In this study, we use a broad range of excitation wavelengths (730-880 nm) to demonstrate that TPEF/SHG coregistration can easily be achieved in unstained tissues by using a simple backscattering geometry. The combined TPEF/SHG technique was applied to imaging a three-dimensional organotypic tissue model (RAFT). The structural and molecular origin of the image-forming signal from the various tissue constituents was determined by simultaneous spectroscopic measurements and confirming immunofluorescence staining. Our results show that at shorter excitation wavelengths (<800 nm), the signal emitted from the extracellular matrix (ECM) is a combination of SHG and TPEF from collagen, whereas at longer excitation wavelengths the ECM signal is exclusively due to SHG. Endogenous cellular signals are consistent with TPEF spectra of cofactors NAD(P)H and FAD at all excitation wavelengths. The reflected SHG intensity follows a quadratic dependence on the excitation power, decays exponentially with depth, and exhibits a spectral dependence in accordance with previous theoretical studies. The use of SHG and TPEF in combination provides complementary information that allows noninvasive, spatially localized in vivo characterization of cell-ECM interactions in unstained thick tissues.
引用
收藏
页码:11014 / 11019
页数:6
相关论文
共 34 条
[11]   Three-dimensional second-harmonic generation imaging with femtosecond laser pulses [J].
Gauderon, R ;
Lukins, PB ;
Sheppard, CJR .
OPTICS LETTERS, 1998, 23 (15) :1209-1211
[12]   Optimization of second-harmonic generation microscopy [J].
Gauderon, R ;
Lukins, PB ;
Sheppard, CJR .
MICRON, 2001, 32 (07) :691-700
[13]   Second and third optical harmonic generation in type I collagen, by nanosecond laser irradiation, over a broad spectral region [J].
Georgiou, E ;
Theodossiou, T ;
Hovhannisyan, V ;
Politopoulos, K ;
Rapti, GS ;
Yova, D .
OPTICS COMMUNICATIONS, 2000, 176 (1-3) :253-260
[14]   Second-harmonic tomography of tissues [J].
Guo, YC ;
Ho, PP ;
Savage, H ;
Harris, D ;
Sacks, P ;
Schantz, S ;
Liu, F ;
Zhadin, N ;
Alfano, RR .
OPTICS LETTERS, 1997, 22 (17) :1323-1325
[15]   Subsurface tumor progression investigated by noninvasive optical second harmonic tomography [J].
Guo, YC ;
Savage, HE ;
Liu, F ;
Schantz, SP ;
Ho, PP ;
Alfano, RR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (19) :10854-10856
[16]   Quantitative near-infrared spectroscopy of cervical dysplasia in vivo [J].
Hornung, R ;
Pham, TH ;
Keefe, KA ;
Berns, MW ;
Tadir, Y ;
Tromberg, BJ .
HUMAN REPRODUCTION, 1999, 14 (11) :2908-2916
[17]  
Kim BM, 2000, LASER SURG MED, V27, P329, DOI 10.1002/1096-9101(2000)27:4<329::AID-LSM5>3.0.CO
[18]  
2-C
[19]   Second harmonic field generated in reflection by an inhomogeneous nonlinear polarization [J].
Le Calvez, A ;
Freysz, E ;
Ducasse, A .
OPTICS COMMUNICATIONS, 1998, 145 (1-6) :135-140
[20]   Multi-photon excitation microscopy and confocal microscopy imaging of in vivo human skin: A comparison [J].
Masters, BR ;
So, PTC .
MICROSCOPY AND MICROANALYSIS, 1999, 5 (04) :282-289