Generating multiple independent retention index data in dual-secondary column comprehensive two-dimensional gas chromatography

被引:46
作者
Bieri, Stefan [1 ]
Marriott, Philip J. [1 ]
机构
[1] RMIT Univ, Sch Appl Sci, Melbourne, Vic 3001, Australia
关键词
D O I
10.1021/ac060869l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method producing simultaneously three retention indexes for compounds has been developed for comprehensive two-dimensional gas chromatography by using a dual secondary column approach ( GC x 2GC). For this purpose, the primary flow of the first dimension column was equally diverted into two secondary microbore columns of identical geometry by means of a three-way flow splitter positioned after the longitudinally modulated cryogenic system. This configuration produced a pair of comprehensive two-dimensional chromatograms and generated retention data on three different stationary phases in a single run. First dimension retention indexes were determined on a polar SolGel-Wax column under linear programmed-temperature conditions according to the van den Dool approach using primary alcohol homologues as the reference scale. Calculation of pseudoisothermal retention indexes in both second dimensions was performed on low-polarity 5% phenyl equivalent polysilphenylene/ siloxane (BPX5) and 14% cyanopropylphenyl/ 86% dimethylpolysiloxane (BP10) columns. To construct a retention correlation map in the second dimension separation space upon which Kovats indexes can be derived, two methods exploiting "isovolatility" relationships of alkanes were developed. The first involved 15 sequential headspace samplings of selected n-alkanes by solid-phase microextraction ( SPME), with each sampling followed by their injection into the GC at predetermined times during the chromatographic run. The second method extended the second dimension retention map and consisted of repetitive introduction of SPME-sampled alkane mixtures at various isothermal conditions incremented over the temperature program range. Calculated second dimension retention indexes were compared with experimental values obtained in conventional one-dimensional GC. A case study mixture including 24 suspected allergens (i.e., fragrance ingredients) was used to demonstrate the feasibility and potential of retention index information in comprehensive 2D-GC.
引用
收藏
页码:8089 / 8097
页数:9
相关论文
共 35 条
[1]   Using comprehensive two-dimensional gas chromatography retention indices to estimate environmental partitioning properties for a complete set of diesel fuel hydrocarbons [J].
Arey, JS ;
Nelson, RK ;
Xu, L ;
Reddy, CM .
ANALYTICAL CHEMISTRY, 2005, 77 (22) :7172-7182
[2]  
Beens J, 1998, HRC-J HIGH RES CHROM, V21, P63
[3]  
Bertsch W, 1999, HRC-J HIGH RES CHROM, V22, P647, DOI 10.1002/(SICI)1521-4168(19991201)22:12<647::AID-JHRC647>3.0.CO
[4]  
2-V
[5]  
Bertsch W, 2000, HRC-J HIGH RES CHROM, V23, P167
[6]   CONSIDERATIONS AND REMARKS ON THE ANALYSIS OF ANTHEMIS-NOBILIS L ESSENTIAL OIL BY CAPILLARY GAS-CHROMATOGRAPHY AND HYPHENATED TECHNIQUES [J].
BICCHI, C ;
FRATTINI, C ;
RAVERDINO, V .
JOURNAL OF CHROMATOGRAPHY, 1987, 411 :237-249
[7]   Reliability of Van den Dool retention indices in the analysis of essential oils [J].
Bicchi, C ;
Binello, A ;
D'Amato, A ;
Rubiolo, P .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1999, 37 (08) :288-294
[8]   Determination of retention indices of polychlorobiphenyls by using other compounds detectable by electron-capture detection or selected polychlorobiphenyls as the reference series [J].
Castello, G ;
Testini, G .
JOURNAL OF CHROMATOGRAPHY A, 1996, 741 (02) :241-249
[9]   Retention index systems:: alternatives to the n-alkanes as calibration standards [J].
Castello, G .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :51-64
[10]   Gas chromatographic retention index system for polychlorinated biphenyls: possibilities and limitations [J].
Castello, G ;
Testini, G .
JOURNAL OF CHROMATOGRAPHY A, 1997, 787 (1-2) :215-225