Calibration of the monochromator bandpass function for the X-ray Rietveld analysis

被引:24
作者
Riello, P
Canton, P
Fagherazzi, G
机构
[1] Dipartimento di Chimica Fisica, Università di Venezia, DD2137
关键词
D O I
10.1017/S0885715600009647
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this paper we propose a fitting procedure to describe the bandpass effect on all x radiation that passes through a focusing graphite monochromator used on the diffracted beam. The proposed bandpass function is: M(2 theta)=1/(1+K(mon1)s(Kmon2)), with s=(2 sin theta)/lambda, where K-mon1 and K-mon2 are constants which have been refined by means of a Rietveld analysis, using a physically modeled background (Riello et al., J. Appl. Crystallogr. 28, 115-120). We have investigated two polycrystalline powders: alpha-Al2O3, and a mixture of alpha and beta-Si3N4. The so-obtained bandpass functions for these materials are close enough to conclude that they depend only on the used experimental setup (in the present case the S-Pert-Philips diffractometer with a graphite focusing manochromator). Knowledge of the bandpass function is important to suitably model the Compton scattering, which is a component of the background scattering. The present procedure allows one to avoid the direct experimental determination of the bandpass function, which requires the use of another monochromator (analyzer) and another tube with an intense white spectrum. (C) 1997 International Centre for Diffraction Data.
引用
收藏
页码:160 / 166
页数:7
相关论文
共 16 条