The PRIMA Study: presentation ischaemia-modified albumin in the emergency department

被引:60
作者
Keating, L. [1 ]
Benger, J. R.
Beetham, R.
Bateman, S.
Veysey, S.
Kendall, J.
Pullinger, R.
机构
[1] John Radcliffe Hosp, Emergency Dept, Oxford OX3 9DU, England
[2] United Bristol Healthcare Trust, Emergency Dept, Acad Dept Emergency Care, Bristol, Avon, England
[3] Univ W England, Fac Hlth & Social Care, Bristol BS16 1QY, Avon, England
[4] Frenchay Hosp, Emegency Dept, Bristol BS16 1LE, Avon, England
[5] Frenchay Hosp, Dept Clin Chem, Bristol BS16 1LE, Avon, England
关键词
D O I
10.1136/emj.2006.036269
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To investigate the diagnostic accuracy of presentation ischaemia-modified albumin (IMA), in addition to cardiac troponin I (TnI), as a strategy to rapidly ascribe low risk to patients with chest pain attending an emergency department, and to determine whether IMA has the potential to reduce transit time in emergency departments. Methods: A prospective observational study was carried out in two emergency departments (belonging to the John Radcliffe Hospital, Oxford, UK; and the Frenchay Hospital, Bristol, UK) of similar size. Consecutive adult patients presenting with features of possible ischaemic cardiac chest pain and a normal electrocardiogram were eligible. The index test (measurement of IMA and TnI at presentation) and reference standard (delayed TnI measurement, taken at least 8 h after pain onset) were applied to all recruited patients. All clinicians were blinded to the results of the index test. Assays were carried out in a single laboratory using standard techniques. Results: 399 patients were recruited; 277 patients had a result for both the index test and reference standard. The sensitivity was 97.6% (95% confidence interval (CI) 87.4 to 99.9), negative predictive value 97% (95% CI 84.2 to 99.9) and specificity 13.6% (95% CI 9.5 to 18.7). Sensitivity analysis showed similar findings in three alternative scenarios. Receiver operating characteristic analysis indicated that a different ``cut-off'' value for IMA would not improve the properties of the test. The median potential time saved (n = 268) was 6 h and 10 min. Conclusion: The diagnostic accuracy of presentation IMA in this study does not support its use as an effective risk stratification tool for patients with chest pain in the emergency department. The sensitivity is insufficiently high, with a small number of false negatives undermining the safety of the test. Frequent false positives produce a low specificity that limits the practical value of the test.
引用
收藏
页码:764 / 768
页数:5
相关论文
共 19 条
  • [1] Markers to define ischemia: Are they ready for prime time use in patients with acute coronary syndromes?
    Adams J.
    [J]. Current Cardiology Reports, 2004, 6 (4) : 253 - 258
  • [2] Ischemia modified albumin improves the sensitivity and negative predictive value of standard cardiac biomarkers for the diagnosis of myocardial ischemia
    Anwaruddin, S
    Januzzi, JL
    Lewandrowski, KB
    Lewandrowski, E
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 258A - 258A
  • [3] Reduced albumin-cobalt binding with transient myocardial ischemia after elective percutaneous transluminal coronary angioplasty: A preliminary comparison to creatine kinase-MB, myoglobin, and troponin I
    Bar-Or, D
    Winkler, JV
    VanBenthuysen, K
    Harris, L
    Lau, E
    Hetzel, FW
    [J]. AMERICAN HEART JOURNAL, 2001, 141 (06) : 985 - 991
  • [4] Bar-Or D, 1999, ANN EMERG MED, V34, pS56
  • [5] Evaluation of human serum albumin cobalt binding assay for the assessment of myocardial ischemia and myocardial infarction
    Bhagavan, NV
    Lai, EM
    Rios, PA
    Yang, JS
    Ortega-Lopez, AM
    Shinoda, H
    Honda, SAA
    Rios, CN
    Sugiyama, CE
    Ha, CE
    [J]. CLINICAL CHEMISTRY, 2003, 49 (04) : 581 - 585
  • [6] The STARD statement for reporting studies of diagnostic accuracy: Explanation and elaboration
    Bossuyt, PM
    Reitsma, JB
    Bruns, DE
    Gatsonis, CA
    Glasziou, PP
    Irwig, LM
    Moher, D
    Rennie, D
    de Vet, HCW
    Lijmer, JG
    [J]. CLINICAL CHEMISTRY, 2003, 49 (01) : 7 - 18
  • [7] ACC/AHA guidelines for the management of patients with unstable angina and non-ST-segment elevation myocardial infarction
    Braunwald, E
    Antman, EM
    Beasley, JW
    Califf, RM
    Cheitlin, MD
    Hochman, JS
    Jones, RH
    Kereiakes, D
    Kupersmith, J
    Levin, TN
    Pepine, CJ
    Schaeffer, JW
    Smith, EE
    Steward, DE
    Theroux, P
    Gibbons, RJ
    Alpert, JS
    Eagle, KA
    Faxon, DP
    Fuster, V
    Gardner, TJ
    Gregoratos, G
    Russell, RO
    Smith, SC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) : 970 - 1056
  • [8] Utility of admission cardiac troponin and "Ischemia Modified Albumin" measurements for rapid evaluation and rule out of suspected acute myocardial infarction in the emergency department
    Collinson, PO
    Gaze, DC
    Bainbridge, K
    Morris, F
    Morris, B
    Price, A
    Goodacre, S
    [J]. EMERGENCY MEDICINE JOURNAL, 2006, 23 (04) : 256 - 261
  • [9] *DOH, 2004, EM CAR
  • [10] FOTHERGILL NJ, 1993, ARCH EMERG MED, V10, P155