Recent advances in myocardial contrast echocardiography

被引:28
作者
Wei, K
Kaul, S
机构
[1] Cardiovascular Division, Medical Center, Univ. of Virginia School of Medicine, Charlottesville
关键词
D O I
10.1097/00001573-199711000-00007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the past few years, significant advances have been made in the production of microbubbles that are more stable in the circulation. Our understanding of the interactions between microbubbles and ultrasound has also led to the development of new ultrasound imaging techiques that result in excellent myocardial opacification after an intravenous administration of microbubbles. This review focuses on advances made with these technologies in the setting of acute coronary syndromes and chronic coronary artery disease.
引用
收藏
页码:539 / 546
页数:8
相关论文
共 36 条
[21]  
NANTO S, 1996, J AM SOC ECHOCARDIOG, V8, P314
[22]  
Porter T R, 1996, J Am Soc Echocardiogr, V9, P779, DOI 10.1016/S0894-7317(96)90468-X
[23]   Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging [J].
Porter, TR ;
Li, SP ;
Kricsfeld, D ;
Armbruster, RW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (04) :791-799
[24]   TRANSIENT MYOCARDIAL CONTRAST AFTER INITIAL EXPOSURE TO DIAGNOSTIC ULTRASOUND PRESSURES WITH MINUTE DOSES OF INTRAVENOUSLY INJECTED MICROBUBBLES - DEMONSTRATION AND POTENTIAL MECHANISMS [J].
PORTER, TR ;
XIE, F .
CIRCULATION, 1995, 92 (09) :2391-2395
[25]   MICROVASCULAR INTEGRITY INDICATES MYOCELLULAR VIABILITY IN PATIENTS WITH RECENT MYOCARDIAL-INFARCTION - NEW INSIGHTS USING MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY [J].
RAGOSTA, M ;
CAMARANO, G ;
KAUL, S ;
POWERS, ER ;
SAREMBOCK, IJ ;
GIMPLE, LW .
CIRCULATION, 1994, 89 (06) :2562-2569
[26]  
SABIA P, 1991, CIRCULATION, V84, pI85
[27]   AN ASSOCIATION BETWEEN COLLATERAL BLOOD-FLOW AND MYOCARDIAL VIABILITY IN PATIENTS WITH RECENT MYOCARDIAL-INFARCTION [J].
SABIA, PJ ;
POWERS, ER ;
RAGOSTA, M ;
SAREMBOCK, IJ ;
BURWELL, LR ;
KAUL, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (26) :1825-1831
[28]   SIMULATED CAPILLARY BLOOD-FLOW MEASUREMENT USING A NONLINEAR ULTRASONIC CONTRAST AGENT [J].
SCHROPE, B ;
NEWHOUSE, VL ;
UHLENDORF, V .
ULTRASONIC IMAGING, 1992, 14 (02) :134-158
[29]   Contractile versus microvascular reserve for the determination of the extent of myocardial salvage after reperfusion - The effect of residual coronary stenosis [J].
Sklenar, J ;
Camarano, G ;
Goodman, NC ;
Ismail, S ;
Jayaweera, AR ;
Kaul, S .
CIRCULATION, 1996, 94 (06) :1430-1440
[30]   Hemodynamic characteristics, myocardial kinetics and microvascular rheology of FS-069, a second-generation echocardiographic contrast agent capable of producing myocardial opacification from a venous injection [J].
Skyba, DM ;
Camarano, G ;
Goodman, NC ;
Price, RJ ;
Skalak, TC ;
Kaul, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (05) :1292-1300