Malrotated Tibial Component Increases Medial Collateral Ligament Tension in Total Knee Arthroplasty

被引:74
作者
Kuriyama, Shinichi [1 ]
Ishikawa, Masahiro [1 ]
Furu, Moritoshi [1 ]
Ito, Hiromu [1 ]
Matsuda, Shuichi [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Orthopaed Surg, Sakyo Ku, Kyoto 6068507, Japan
关键词
total knee arthroplasty; medial collateral ligament; tibial component; malrotation; computer simulation; POSTERIOR CRUCIATE LIGAMENT; TECHNOLOGY-IN-ARTHROPLASTY; JOINT CONTACT; STRUCTURAL-PROPERTIES; REPLACEMENT; FLEXION; FORCES; OSTEOARTHRITIS; POLYETHYLENE; BIOMECHANICS;
D O I
10.1002/jor.22711
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Malrotation of the tibial component can lead to complications after total knee arthroplasty (TKA). Despite reports of internal rotation being associated with more severe pain or stiffness than external rotation, the biomechanical reasons remain largely unknown. We used a computer simulation model and evaluated traction forces in the lateral collateral ligament (LCL) and medial collateral ligament (MCL) with a malrotated tibial component during squatting. We also examined tibiofemoral and patellofemoral contact forces and stresses under similar conditions. A dynamic musculoskeletal knee model was simulated in three different constrained tibial geometries with a prototype component. The testing conditions were changed between 15 degrees external and 15 degrees internal rotation of the tibial component. With internal rotation of the tibial component, the MCL force increased progressively; the LCL force also increased, but only up to less than half of the MCL force values. A higher degree of constraint of the tibial component was associated with greater femoral rotational movement and higher MCL forces. The tibiofemoral and patellofemoral contact forces were not influenced by malrotation of the tibial component, but the contact stresses increased because of decreased contact area. This altered loading condition could cause patient complaints and polyethylene problems after TKA. (c) 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:1658-1666, 2014.
引用
收藏
页码:1658 / 1666
页数:9
相关论文
共 34 条
[1]
2003 Hap Paul Award paper of the international society for technology in arthroplasty [J].
Banks, SA ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :809-816
[2]
Barrack RL, 2001, CLIN ORTHOP RELAT R, P46
[3]
Internal Rotation of the Tibial Component is Frequent in Stiff Total Knee Arthroplasty [J].
Bedard, Martin ;
Vince, Kelly G. ;
Redfern, John ;
Collen, Stacy R. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (08) :2346-2355
[4]
Geometrical changes of knee ligaments and patellar tendon during passive flexion [J].
Belvedere, C. ;
Ensini, A. ;
Feliciangeli, A. ;
Cenni, F. ;
D'Angeli, V. ;
Giannini, S. ;
Leardini, A. .
JOURNAL OF BIOMECHANICS, 2012, 45 (11) :1886-1892
[5]
Malrotation causing patellofemoral complications after total knee arthroplasty [J].
Berger, RA ;
Crossett, LS ;
Jacobs, JJ ;
Rubash, HE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) :144-153
[6]
ARTICULAR CONTACT IN A 3-DIMENSIONAL MODEL OF THE KNEE [J].
BLANKEVOORT, L ;
KUIPER, JH ;
HUISKES, R ;
GROOTENBOER, HJ .
JOURNAL OF BIOMECHANICS, 1991, 24 (11) :1019-1031
[7]
Brantigan OC, 1941, J BONE JOINT SURG, V23, P44
[8]
Gait knee kinematic alterations in medial osteoarthritis: three dimensional assessment [J].
Bytyqi, Dafina ;
Shabani, Bujar ;
Lustig, Sebastien ;
Cheze, Laurence ;
Gjurgjeala, Natyra Karahoda ;
Neyret, Philippe .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (06) :1191-1198
[9]
Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[10]
The attachments of the fiber bundles of the posterior cruciate ligament: An anatomic study [J].
Edwards, Andrew ;
Bull, Anthony M. J. ;
Amis, Andrew A. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (03) :284-290