共 31 条
Quantitative CT Scanning Analysis of Pure Ground-Glass Opacity Nodules Predicts Further CT Scanning Change
被引:159
作者:
Bak, So Hyeon
[1
,2
]
Lee, Ho Yun
[1
,2
]
Kim, Jae-Hun
[1
,2
]
Um, Sang-Won
[3
]
Kwon, O. Jung
[3
]
Han, Joungho
[4
]
Kim, Hong Kwan
[5
]
Kim, Jhingook
[5
]
Lee, Kyung Soo
[1
,2
]
机构:
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Ctr Imaging Sci, Seoul, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Div Resp & Crit Med,Dept Internal Med, Seoul, South Korea
[4] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Pathol, Seoul, South Korea
[5] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Thorac & Cardiovasc Surg, Seoul, South Korea
来源:
关键词:
CT scanning;
ground-glass opacity nodule;
lung cancer;
RESPIRATORY SOCIETY CLASSIFICATION;
SUBSOLID PULMONARY NODULES;
THIN-SECTION CT;
LUNG ADENOCARCINOMA;
INTERNATIONAL ASSOCIATION;
IMAGING BIOMARKERS;
PATIENT SURVIVAL;
MANAGEMENT;
GROWTH;
EVOLUTION;
D O I:
10.1378/chest.15-0034
中图分类号:
R4 [临床医学];
学科分类号:
100218 [急诊医学];
摘要:
BACKGROUND: We sought to determine whether quantitative analysis of lung adenocarcinoma manifesting as a ground-glass opacity (GGO) nodule (GGN) on initial CT scans can predict further CT scanning change or rate of growth. METHODS: This retrospective study included patients with lung adenocarcinoma manifesting as pure GGN on initial CT scans who were followed up with interval CT scanning until resection. All pure GGNs were classified based on CT scanning interval change in three subgroups as follows: group A (development of solid component), group B (growth of GGO component), and group C (no change in size). Nodule size, volume, density, mass, and CT scanning attenuation values were assessed from initial CT data sets. RESULTS: Fifty-four pure GGNs were enrolled and classified into group A (n = 9), group B (n = 25), and group C (n = 20). Nodule size, volume, mass, and density of the GGNs in each subgroup were not significantly different. The 97.5th percentile CT scanning attenuation value and slope of CT scanning attenuation values from the 2.5th to the 97.5th percentile were significantly different among the three subgroups (P = .02, P < .00). Three of nine (33%) pure GGNs showing a new solid component developed a solid component within 6 months. CONCLUSIONS: The 97.5th percentile CT scanning attenuation value and slope of CT scanning attenuation values from the 2.5th to the 97.5th percentile could be helpful in predicting future CT scanning change and growth rate of pure GGNs. Pure GGNs showing higher 97.5th percentile CT scanning attenuation values and steeper slopes of CT scanning attenuation values may require more frequent follow-up than the usual interval of 6 months.
引用
收藏
页码:180 / 191
页数:12
相关论文

