Coordinate transformations for BEAM/EGSnrc Monte Carlo dose calculations of non-coplanar fields received from a DICOM-compliant treatment planning system

被引:8
作者
Thebaut, J. [1 ]
Zavgorodni, S.
机构
[1] Univ Victoria, Dept Phys & Astron, Victoria, BC V8W 2Y2, Canada
[2] Vancouver Island Ctr, Dept Med Phys, Victoria, BC, Canada
关键词
D O I
10.1088/0031-9155/51/23/N06
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Monte Carlo (MC) method provides the most accurate to-date dose calculations in heterogeneous media and complex geometries, and this spawns increasing interest in incorporating MC calculations in the treatment planning quality assurance process. This process involves MC dose calculations for the treatment plans produced clinically. Commonly used in radiotherapy, MC codes are BEAMnrc and DOSXYZnrc, which transport particles in a coordinate system (c.s.) that has been established historically and does not correspond to the c.s. of treatment planning systems (TPSs). Relative rotations of these c.s. are not straightforward, especially for non-coplanar treatments. Transformation equations are therefore required to re-calculate a treatment plan using BEAM/DOSXYZnrc codes. This paper presents such transformations for beam angles defined in a DICOM-compliant treatment planning coordinate system. Verification of the derived transformations with two three-field plans simulated on a phantom using TPS as well as MC codes has been performed demonstrating exact geometrical agreement of the MC treatment fields' placement.
引用
收藏
页码:N441 / N449
页数:9
相关论文
共 23 条
[1]   Monte Carlo-based lung cancer treatment planning incorporating PET-defined target volumes [J].
Chetty, Indrin J. ;
Fernando, Shaneli ;
Kessler, Marc L. ;
Mcshan, Daniel L. ;
Brooks, Cassandra ;
Haken, Randall K. Ten ;
Kong, Feng-Ming Spring .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (04) :65-76
[2]   Insulin treatment and sVCAM-1, sICAM-1 and vWF in patients with diabetes mellitus type 2 [J].
Francuz, T ;
Siemianowicz, K ;
Gminski, J ;
Telega, A ;
Syzdol, M ;
Goss, M .
ATHEROSCLEROSIS SUPPLEMENTS, 2003, 4 (02) :144-144
[3]   Development and validation of a BEAMnrc component module for accurate Monte Carlo modelling of the Varian dynamic Millennium multileaf collimator [J].
Heath, E ;
Seuntjens, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (24) :4045-4063
[4]   Monte Carlo as a four-dimensional radiotherapy treatment-planning tool to account for respiratory motion [J].
Keall, PJ ;
Siebers, JV ;
Joshi, S ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (16) :3639-3648
[5]   Monte Carlo dose calculations for dynamic IMRT treatments [J].
Keall, PJ ;
Siebers, JV ;
Arnfield, M ;
Kim, JO ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04) :929-941
[6]   Routine IMRT verification by means of an automated Monte Carlo simulation system [J].
Leal, A ;
Sánchez-Doblado, F ;
Arráns, R ;
Roselló, J ;
Pavón, EC ;
Lagares, JI .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01) :58-68
[7]   Monte Carlo based treatment planning for modulated electron beam radiation therapy [J].
Lee, MC ;
Deng, J ;
Li, JS ;
Jiang, SB ;
Ma, CM .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (08) :2177-2199
[8]   Radiotherapy equipment standards from the International Electrotechnical Commission [J].
Lillicrap, SC ;
Higson, GR ;
O'Connor, AJ .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (852) :1225-1228
[9]   A method of simulating dynamic multileaf collimators using Monte Carlo techniques for intensity-modulated radiation therapy [J].
Liu, HH ;
Verhaegen, F ;
Dong, L .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (09) :2283-2298
[10]   Monitor unit calculation for Monte Carlo treatment planning [J].
Ma, CM ;
Price, RA ;
Li, JS ;
Chen, L ;
Wang, L ;
Fourkal, E ;
Qin, L ;
Yang, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (09) :1671-1687