Ion Fusion of High-Resolution LC MS-Based Metabolomics Data to Discover More Reliable Biomarkers

被引:38
作者
Zeng, Zhongda [1 ]
Liu, Xinyu [1 ]
Dai, Weidong [1 ]
Yin, Peiyuan [1 ]
Zhou, Lina [1 ]
Huang, Qiang [1 ]
Lin, Xiaohui [2 ]
Xu, Guowang [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
[2] Dalian Univ Technol, Sch Comp Sci & Technol, Dalian 116024, Peoples R China
基金
中国国家自然科学基金;
关键词
SPECTROMETRY-BASED METABOLOMICS; ORBITRAP MASS-SPECTROMETER; LIQUID-CHROMATOGRAPHY; ACCURATE MASS; SERUM; IDENTIFICATION; METABONOMICS; VALIDATION; TOOLS;
D O I
10.1021/ac500878x
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
A systematic approach for the fusion of associated ions from a common molecule was developed to generate "one feature for one peak" metabolomics data. This approach guarantees that each molecule is equally selected as a potential biomarker and may largely enhance the chance to obtain reliable findings without employing redundant ion information. The ion fusion is based on low mass variation in contrast to the theoretical calculation measured by a high-resolution mass spectrometer, such as LTQ orbitrap, and a high correlation of ion pairs from the same molecule. The mass characteristics of isotopic distribution, neutral loss, and adduct ions were simultaneously applied to inspect each extracted ion in the range of a predefined retention time window. The correlation coefficient was computed with the corresponding intensities of each ion pair among all experimental samples. Serum metabolomics data for the investigation of hepatocellular carcinoma (HCC) and healthy controls were utilized as an example to demonstrate this strategy. In total, 609 and 1084 ion pairs were respectively found meeting one or more criteria for fusion, and therefore fused to 106 and 169 metabolite features of the datasets in the positive and negative modes, respectively. The important metabolite features were separately discovered and compared to distinguish the HCC from the healthy controls using the two datasets with and without ion fusion. The results show that the developed method can be an effective tool to process high-resolution mass spectrometry data in "omics" studies.
引用
收藏
页码:3793 / 3800
页数:8
相关论文
共 22 条
[1]
The role of chemometrics in single and sequential extraction assays: A review Part I. Extraction procedures, uni- and bivariate techniques and multivariate variable reduction techniques for pattern recognition [J].
Abollino, Ornella ;
Malandrino, Mery ;
Giacomino, Agnese ;
Mentasti, Edoardo .
ANALYTICA CHIMICA ACTA, 2011, 688 (02) :104-121
[2]
Large-scale human metabolomics studies: A strategy for data (pre-) processing and validation [J].
Bijlsma, S ;
Bobeldijk, L ;
Verheij, ER ;
Ramaker, R ;
Kochhar, S ;
Macdonald, IA ;
van Ommen, B ;
Smilde, AK .
ANALYTICAL CHEMISTRY, 2006, 78 (02) :567-574
[3]
Automated workflows for accurate mass-based putative metabolite identification in LC/MS-derived metabolomic datasets [J].
Brown, Marie ;
Wedge, David C. ;
Goodacre, Royston ;
Kell, Douglas B. ;
Baker, Philip N. ;
Kenny, Louise C. ;
Mamas, Mamas A. ;
Neyses, Ludwig ;
Dunn, Warwick B. .
BIOINFORMATICS, 2011, 27 (08) :1108-1112
[4]
Serum 27-nor-5β-Cholestane-3,7,12,24,25 Pentol Glucuronide Discovered by Metabolomics as Potential Diagnostic Biomarker for Epithelium Ovarian Cancer [J].
Chen, Jing ;
Zhang, Xiaoyan ;
Cao, Rui ;
Lu, Xin ;
Zhao, Sumin ;
Fekete, Agnes ;
Huang, Qiang ;
Schmitt-Kopplin, Philippe ;
Wang, Yisheng ;
Xu, Zhiliang ;
Wan, Xiaoping ;
Wu, Xiaohua ;
Zhao, Naiqing ;
Xu, Congjian ;
Xu, Guowang .
JOURNAL OF PROTEOME RESEARCH, 2011, 10 (05) :2625-2632
[5]
Metabolic profiling of serum using Ultra Performance Liquid Chromatography and the LTQ-Orbitrap mass spectrometry system [J].
Dunn, Warwick B. ;
Broadhurst, David ;
Brown, Marie ;
Baker, Philip N. ;
Redman, Christopher W. G. ;
Kenny, Louise C. ;
Kell, Douglas B. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (02) :288-298
[6]
Procedures for large-scale metabolic profiling of serum and plasma using gas chromatography and liquid chromatography coupled to mass spectrometry [J].
Dunn, Warwick B. ;
Broadhurst, David ;
Begley, Paul ;
Zelena, Eva ;
Francis-McIntyre, Sue ;
Anderson, Nadine ;
Brown, Marie ;
Knowles, Joshau D. ;
Halsall, Antony ;
Haselden, John N. ;
Nicholls, Andrew W. ;
Wilson, Ian D. ;
Kell, Douglas B. ;
Goodacre, Royston .
NATURE PROTOCOLS, 2011, 6 (07) :1060-1083
[7]
Targeted Metabolomics for Biomarker Discovery [J].
Griffiths, William J. ;
Koal, Therese ;
Wang, Yuqin ;
Kohl, Matthias ;
Enot, David P. ;
Deigner, Hans-Peter .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (32) :5426-5445
[8]
High-resolution extracted ion chromatography, a new tool for metabolomics and lipidomics using a second-generation orbitrap mass spectrometer [J].
Koulman, Albert ;
Woffendin, Gary ;
Narayana, Vinod K. ;
Welchman, Helen ;
Crone, Catharina ;
Volmer, Dietrich A. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (10) :1411-1418
[9]
MetAlign 3.0: performance enhancement by efficient use of advances in computer hardware [J].
Lommen, Arjen ;
Kools, Harrie J. .
METABOLOMICS, 2012, 8 (04) :719-726
[10]
Computing Fragmentation Trees from Tandem Mass Spectrometry Data [J].
Rasche, Florian ;
Svatos, Ales ;
Maddula, Ravi Kumar ;
Boettcher, Christoph ;
Boecker, Sebastian .
ANALYTICAL CHEMISTRY, 2011, 83 (04) :1243-1251