Selective determination of quinones by high-performance liquid chromatography with on-line post column ultraviolet irradiation and peroxyoxalate chemiluminescence detection

被引:32
作者
Ahmed, Sameh [1 ]
Fujii, Shuu [1 ]
Kishikawa, Naoya [1 ]
Ohba, Yoshihito [1 ]
Nakashima, Kenichiro [1 ]
Kuroda, Naotaka [1 ]
机构
[1] Nagasaki Univ, Grad Sch Biomed Sci, Course Pharmaceut Sci, Nagasaki 8528521, Japan
关键词
peroxyoxalate chemiluminescence detection; quinones; UV irradiation; HPLC; hydrogen peroxide;
D O I
10.1016/j.chroma.2006.07.078
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new HPLC method was developed for the simultaneous determination of quinones with peroxyoxalate chemiluminescence (PO-CL) detection following on-line UV irradiation. Quinones [i.e., 1,2-naphthoquinone, 1,4-naphthoquinone, 9,10-anthraquinone, 9,10-phenanthrenequinone] were UV irradiated (254 nm, 15 W) to generate hydrogen peroxide and a fluorescent product that were determined via PO-CL detection. Generation of hydrogen peroxide from quinones with on-line UV irradiation was confirmed using flow injection analysis (FIA) system whereby incorporating an enzyme column reactor immobilized with catalase. Moreover, the structure of the produced fluorophore was confirmed using LC-MS, IR, and H-1 NMR. Afterwards, the conditions for UV irradiation and PO-CL detection were optimized. The separation of four quinones by HPLC was accomplished isocratically on an ODS column within 25 min. The detection limits (signal-to-noise ratio = 3) were 6.0 pmol/injection for 1,2-naphthoquinone, 4.4 pmol/injection for 1,4-naphthoquinone, 0.2 pmol/injection for 9, 10-anthraquinone, and 0.45 pmol/injection for 9, 10-phenanthrenequinone. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:76 / 82
页数:7
相关论文
共 27 条
[1]   PHOTOCHEMICAL-REACTION COUPLED TO SOLID-STATE PEROXYOXALATE CHEMILUMINESCENCE FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETECTION OF COMPOUNDS HAVING WEAK CHROMOPHORES [J].
AICHINGER, I ;
GUBITZ, G ;
BIRKS, JW .
JOURNAL OF CHROMATOGRAPHY, 1990, 523 :163-172
[2]   High-performance liquid chromatographic validated assay of doxorubicin in rat plasma and tissues [J].
Alvarez-Cedrón, L ;
Sayalero, ML ;
Lanao, JM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 721 (02) :271-278
[3]   Photosystem two [J].
Barber, J .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 1998, 1365 (1-2) :269-277
[4]   Development of a validated liquid chromatography method for the simultaneous determination of eight fat-soluble vitamins in biological fluids after solid-phase extraction [J].
Chatzimichalakis, PF ;
Samanidou, VF ;
Papadoyannis, IN .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (02) :289-296
[5]   Determination of four quinones in diesel exhaust particles, SRM 1649a, an atmospheric PM2.5 [J].
Cho, AK ;
Di Stefano, E ;
You, Y ;
Rodriguez, CE ;
Schmitz, DA ;
Kumagai, Y ;
Miguel, AH ;
Eiguren-Fernandez, A ;
Kobayashi, T ;
Avol, E ;
Froines, JR .
AEROSOL SCIENCE AND TECHNOLOGY, 2004, 38 :68-81
[6]   BIOCHEMICAL, PHYSIOLOGICAL AND MEDICAL ASPECTS OF UBIQUINONE FUNCTION [J].
ERNSTER, L ;
DALLNER, G .
BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR BASIS OF DISEASE, 1995, 1271 (01) :195-204
[7]   High performance liquid chromatographic determination of some co-administered anticancer drugs in pharmaceutical preparations and in spiked human plasma [J].
Fahmy, OT ;
Korany, MA ;
Maher, HM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (05) :1099-1107
[8]  
GARCIACAMNA AM, 2001, CHEMILUMINESCENCE AN, V7, P141
[9]  
HU OYP, 1995, J CHROMATOGR B, V666, P299
[10]   Flow-injection determination of vitamin K3 by a chemiluminescence sensor [J].
Huang, YM ;
Chen, ZQ ;
Zhang, ZJ .
ANALYTICAL SCIENCES, 1999, 15 (12) :1227-1230