Selective determination of quinones by high-performance liquid chromatography with on-line post column ultraviolet irradiation and peroxyoxalate chemiluminescence detection

被引:32
作者
Ahmed, Sameh [1 ]
Fujii, Shuu [1 ]
Kishikawa, Naoya [1 ]
Ohba, Yoshihito [1 ]
Nakashima, Kenichiro [1 ]
Kuroda, Naotaka [1 ]
机构
[1] Nagasaki Univ, Grad Sch Biomed Sci, Course Pharmaceut Sci, Nagasaki 8528521, Japan
关键词
peroxyoxalate chemiluminescence detection; quinones; UV irradiation; HPLC; hydrogen peroxide;
D O I
10.1016/j.chroma.2006.07.078
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new HPLC method was developed for the simultaneous determination of quinones with peroxyoxalate chemiluminescence (PO-CL) detection following on-line UV irradiation. Quinones [i.e., 1,2-naphthoquinone, 1,4-naphthoquinone, 9,10-anthraquinone, 9,10-phenanthrenequinone] were UV irradiated (254 nm, 15 W) to generate hydrogen peroxide and a fluorescent product that were determined via PO-CL detection. Generation of hydrogen peroxide from quinones with on-line UV irradiation was confirmed using flow injection analysis (FIA) system whereby incorporating an enzyme column reactor immobilized with catalase. Moreover, the structure of the produced fluorophore was confirmed using LC-MS, IR, and H-1 NMR. Afterwards, the conditions for UV irradiation and PO-CL detection were optimized. The separation of four quinones by HPLC was accomplished isocratically on an ODS column within 25 min. The detection limits (signal-to-noise ratio = 3) were 6.0 pmol/injection for 1,2-naphthoquinone, 4.4 pmol/injection for 1,4-naphthoquinone, 0.2 pmol/injection for 9, 10-anthraquinone, and 0.45 pmol/injection for 9, 10-phenanthrenequinone. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:76 / 82
页数:7
相关论文
共 27 条
[21]   Validated HPLC method for determination of sennosides A and B in senna tablets [J].
Sun, SW ;
Su, HT .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (05) :881-894
[22]   Analytical applications of peroxyoxalate chemiluminescence [J].
Tsunoda, M ;
Imai, K .
ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) :13-23
[23]   A sensitive and rapid FIA with an immobilized enzyme column reactor and peroxyoxalate chemiluminescence detection for the determination of total D-amino acids in human plasma [J].
Wada, M ;
Kuroda, N ;
Akiyama, S ;
Nakashima, K .
ANALYTICAL SCIENCES, 1997, 13 (06) :945-950
[24]   Determination of organic peroxides by liquid chromatography with on-line post-column ultraviolet irradiation and peroxyoxalate chemiluminescence detection [J].
Wada, M ;
Inoue, K ;
Ihara, A ;
Kishikawa, N ;
Nakashima, K ;
Kuroda, N .
JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) :189-195
[25]   Simultaneous determination of vitamin K analogs in human serum by sensitive and selective high-performance liquid chromatography with electrochemical detection [J].
Wakabayashi, H ;
Onodera, K ;
Yamato, S ;
Shimada, K .
NUTRITION, 2003, 19 (7-8) :661-665
[26]   Subzero-temperature liquid-liquid extraction of benzodiazepines for high performance liquid chromatography [J].
Yoshida, M ;
Akane, A .
ANALYTICAL CHEMISTRY, 1999, 71 (09) :1918-1921
[27]   Determination of doxorubicin and its metabolites in rat serum and bile by LC: application to preclinical pharmacokinetic studies [J].
Zhou, QY ;
Chowbay, B .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (04) :1063-1074