Airway resistance measured by the interrupter technique: normative data for 2-10 year olds of three ethnicities

被引:49
作者
McKenzie, SA [1 ]
Chan, E [1 ]
Dundas, I [1 ]
Bridge, PD [1 ]
Pao, CS [1 ]
Mylonopoulou, M [1 ]
Healy, MJR [1 ]
机构
[1] Royal London Hosp, London E1 1BB, England
关键词
D O I
10.1136/adc.87.3.248
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background and Aims: The measurement of airway resistance using the interrupter technique (R-int) is feasible in preschool children and other subjects unable to undertake spirometry. This makes it potentially useful for the measurement of lung function in these groups. Commercial devices use different algorithms to measure pressure and flow from which R-int is derived. This study provides normative values for British children using devices from a single manufacturer. Methods: R-int was measured in 236 healthy children of three ethnic groups (Afro-Caribbean and black African, Bangladeshi, and white British) aged 2-10 years using Micro Medical devices. Software in the devices calculated R-int from pressure measured by the two point, back extrapolation method from the pressure transient during valve closure, with flow measured just before valve closure. Results: R-int is related to both age and height, but when age is allowed for there is not a significant relation with height. Neither gender nor any of the ethnicities studied was significantly related to R-int. Discussion: These measurements in healthy children using this technique may be used as reference data for similar populations.
引用
收藏
页码:248 / 251
页数:4
相关论文
共 31 条
[1]  
*AM THOR SOC, 1991, AM REV RESPIR DIS, V144, P1218
[2]   Lung function measurement in awake young children [J].
Bisgaard, H ;
Klug, B .
EUROPEAN RESPIRATORY JOURNAL, 1995, 8 (12) :2067-2075
[3]   A portable device based on the interrupter technique to measure bronchodilator response in schoolchildren [J].
Bridge, PD ;
Lee, H ;
Silverman, M .
EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (07) :1368-1373
[4]  
Bridge PD, 2001, ARCH DIS CHILD, V84, P531
[5]   Airway resistance measured by the interrupter technique: expiration or inspiration, mean or median? [J].
Bridge, PD ;
McKenzie, SA .
EUROPEAN RESPIRATORY JOURNAL, 2001, 17 (03) :495-498
[6]   Measurement of airway resistance using the interrupter technique in preschool children in the ambulatory setting [J].
Bridge, PD ;
Ranganathan, S ;
McKenzie, SA .
EUROPEAN RESPIRATORY JOURNAL, 1999, 13 (04) :792-796
[7]   EVALUATION OF THE INTERRUPTER TECHNIQUE FOR THE USE OF ASSESSING AIRWAY-OBSTRUCTION IN CHILDREN [J].
CARTER, ER ;
STECENKO, AA ;
POLLOCK, BH ;
JAEGER, MJ .
PEDIATRIC PULMONOLOGY, 1994, 17 (04) :211-217
[8]  
Carter ER, 1997, EUR RESPIR J, V10, P1428
[9]   How should airways resistance be measured in young children: mask or mouthpiece? [J].
Child, F ;
Clayton, S ;
Davies, S ;
Fryer, AA ;
Jones, PW ;
Lenney, W .
EUROPEAN RESPIRATORY JOURNAL, 2001, 17 (06) :1244-1249
[10]   BODY-MASS INDEX CENTILE CHARTS TO ASSESS FATNESS OF BRITISH CHILDREN [J].
CHINN, S ;
RONA, RJ .
ARCHIVES OF DISEASE IN CHILDHOOD, 1995, 73 (01) :87-87