Lateral force calibration in atomic force microscopy: A new lateral force calibration method and general guidelines for optimization

被引:175
作者
Cannara, Rachel J.
Eglin, Michael
Carpick, Robert W.
机构
[1] Univ Wisconsin, Dept Engn Phys, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Phys, Madison, WI 53706 USA
基金
美国国家科学基金会;
关键词
D O I
10.1063/1.2198768
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Proper force calibration is a critical step in atomic and lateral force microscopies (AFM/LFM). The recently published torsional Sader method [C. P. Green , Rev. Sci. Instrum. 75, 1988 (2004)] facilitates the calculation of torsional spring constants of rectangular AFM cantilevers by eliminating the need to obtain information or make assumptions regarding the cantilever's material properties and thickness, both of which are difficult to measure. Complete force calibration of the lateral signal in LFM requires measurement of the lateral signal deflection sensitivity as well. In this article, we introduce a complete lateral force calibration procedure that employs the torsional Sader method and does not require making contact between the tip and any sample. In this method, a colloidal sphere is attached to a "test" cantilever of the same width, but different length and material as the "target" cantilever of interest. The lateral signal sensitivity is calibrated by loading the colloidal sphere laterally against a vertical sidewall. The signal sensitivity for the target cantilever is then corrected for the tip length, total signal strength, and in-plane bending of the cantilevers. We discuss the advantages and disadvantages of this approach in comparison with the other established lateral force calibration techniques, and make a direct comparison with the "wedge" calibration method. The methods agree to within 5%. The propagation of errors is explicitly considered for both methods and the sources of disagreement discussed. Finally, we show that the lateral signal sensitivity is substantially reduced when the laser spot is not centered on the detector. (c) 2006 American Institute of Physics.
引用
收藏
页数:11
相关论文
共 29 条
[1]  
BEER FP, 2001, MECH MATER, P762
[2]   Force calibration in lateral force microscopy [J].
Cain, RG ;
Biggs, S ;
Page, NW .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2000, 227 (01) :55-65
[3]   Quantitative comparison of three calibration techniques for the lateral force microscope [J].
Cain, RG ;
Reitsma, MG ;
Biggs, S ;
Page, NW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (08) :3304-3312
[4]   Cantilever tilt compensation for variable-load atomic force microscopy [J].
Cannara, RJ ;
Brukman, MJ ;
Carpick, RW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (05)
[5]   Lateral stiffness: A new nanomechanical measurement for the determination of shear strengths with friction force microscopy [J].
Carpick, RW ;
Ogletree, DF ;
Salmeron, M .
APPLIED PHYSICS LETTERS, 1997, 70 (12) :1548-1550
[6]   Scratching the surface: Fundamental investigations of tribology with atomic force microscopy [J].
Carpick, RW ;
Salmeron, M .
CHEMICAL REVIEWS, 1997, 97 (04) :1163-1194
[7]  
CHOI D, 2006, THESIS POSTECH U
[8]   A NONDESTRUCTIVE METHOD FOR DETERMINING THE SPRING CONSTANT OF CANTILEVERS FOR SCANNING FORCE MICROSCOPY [J].
CLEVELAND, JP ;
MANNE, S ;
BOCEK, D ;
HANSMA, PK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02) :403-405
[9]   The determination of atomic force microscope cantilever spring constants via dimensional methods for nanomechanical analysis [J].
Clifford, CA ;
Seah, MP .
NANOTECHNOLOGY, 2005, 16 (09) :1666-1680
[10]   Measuring normal and friction forces acting on individual fine particles [J].
Ecke, S ;
Raiteri, R ;
Bonaccurso, E ;
Reiner, C ;
Deiseroth, HJ ;
Butt, HJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (11) :4164-4170